Table 20. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet
controller.
PCNTNW-NW-026 The MSM is unable to parse a required custom keyword.
Explanation: You typed an incorrect parameter keyword.
Action: Reinstall the device driver using the correct keyword.
PCNTNW-NW-054 The adapter did not respond to the initialization command.
Explanation: The adapter did not respond when the device driver tried to initialize it.
Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, see
"Starting the diagnostic programs" on page 96 and run the diagnostic programs.
PCNTNW-NW-058 The adapter did not respond to the initialization command.
Explanation: The interrupt request (IRQ) setting might not be valid or the EEPROM
information might be incorrect.
Action: Make sure that the IRQ settings are correct in the Configuration/Setup Utility
program. for information on setting the interrupt requests. If the IRQ settings are correct, call
for service.
PCNTNW-NW-066 The cable might be disconnected from the adapter.
Explanation: The cable might be disconnected from the server Ethernet port.
Action: Verify that a cable is connected to the Ethernet port.
PCNTNW-NW-071 The matching virtual adapter could not be found.
Explanation: You tried to load another instance of the driver with a different I/O address. This
new adapter could not be found.
Action: Verify that you installed an IBM Netfinity 10/100 Fault Tolerant Adapter and make
sure that the adapter is seated correctly. If the adapter is seated correctly, call for service.
PCNTNW-NW-072 A resource tag is unavailable.
Explanation: The device driver tried to allocate some resources that were not available.
Action: Add more memory, or free some memory resources in the server. Then, restart the
server.
PCNTNW-NW-073 Unable to allocate memory
Explanation: The device driver failed to allocate the memory needed for normal operation.
Action: Add more memory, or free some memory resources in the server. Then, restart the
server.
PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation: An attempt was made to initialize a given hardware interrupt. The attempt was
not successful.
Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, see
"Starting the diagnostic programs" on page 96 and run the diagnostic programs.
If you have an Ethernet adapter installed, make sure that the adapter does not share an IRQ
with any other device.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the Link Support
Layer (LSL).
Explanation: An error occurred while the device driver was trying to register with the LSL.
Action: Check the version of the NetWare or IntraNetWare operating system. Make sure that
this device driver is correct for the version of NetWare or IntraNetWare that you are using.
Restart the server.