2. Install non-locking swivel casters on the fryer rear channel only.
3. Do not use more than two metal shims
per caster.
4. There are no thread adjustments for the
swivel casters.
e. If the floor is uneven or has a decided slope,
it is recommended to place the fryer on a
smooth platform. Do not rely on leg thread
or caster shims for adjustments.
f.
If the fryer is moved, re-level the fryer
following the instructions given in Steps
3.3.a-c.
g. This fryer must be restrained to prevent
tipping when installed in order to avoid the splashing of hot liquid. The means of restraint may
depend on the type of application, such as connecting to a battery of appliances or installing the
fryer in an alcove, or by separate means, such as restraining devices. A bracket has been provided
on the fryer back panel for this purpose.
The install must be reviewed at the time of installation to ensure it meets the intent of these
instructions. The on-site supervisor and/or operator(s) should be made aware that there is a
restraint on the appliance and, if disconnection of the restraint is necessary, to reconnect this
restraint after the appliance has been returned to its originally installed position.
The fryer MUST be connected to the voltage and phase as specified on the rating and serial number
A ground wire MUST be connected to the ground terminal provided near the input power terminal
block.
3.4 ELECTRICAL CONNECTIONS:
Service connections should be made through the back lower portion of the fryer power input terminal
block component box located under the control wireway. It is recommended that this connection be
made by means of an approved, flexible-metallic or rubber-covered electrical cable and a quick-
disconnect plug. This connection should be made by means of a CE, UL,
disconnect plug. If rigid or flexible-metal conduit connections are required, they must be made through
the rear portion of the fryer cabinet, to the fryer input terminal block.
CONNECTIONS MUST BE MADE BY QUALIFIED SERVICE PERSONNEL ONLY.
a. Wiring Diagram: It is attached to the inside of the fryer door. Amperage for each unit depends on
the type of installation and accessories supplied with the unit.
CAUTIONS
plate located on the back of the fryer door.
Plan and carry out installation in accordance with local codes.
8
WARNING!
IF OPTIONAL SWIVEL CASTERS
ARE USED, LOCKING CASTERS
MUST BE INSTALLED ON THE
FRYER FRONT CHANNEL.
FAILURE TO LOCK CASTERS
PRIOR TO OPERATING THE
FRYER MAY CAUSE THE FRYER
TO MOVE AND CAUSE INJURY
TO THE OPERATOR.
UL, or CSA approved quick-
C

Advertisement