Extended Function Display Selection (Pr. 30 ); Frequency Jump (Pr. 31 To Pr. 36 ) - Mitsubishi FR-S500 Instruction Manual

Transistorized inverter 3.7k-na / 0.75k-na
Hide thumbs Also See for FR-S500:
Table of Contents

Advertisement

Explanation of functions (parameters)
2.3.15 Extended function display selection (Pr. 30
Used to display the extended function parameters.
Refer to page 48 for the extended function parameter list.
Refer to the instruction manual (basic) for the parameter setting method.
Parameter
Name
Extended function
30
display selection
2.3.16 Frequency jump (Pr. 31
When it is desired to avoid
resonance attributable to the
natural frequency of a
mechanical system, these
parameters allow resonant
frequencies to be jumped. Up
to three areas may be set,
with the jump frequencies set
to either the top or bottom
point of each area.
The value set to 1A, 2A or 3A
is a jump point and operation
is performed at this frequency.
Parameter
Name
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
<Setting>
To fix the frequency at 30Hz between Pr. 33 and Pr. 34
(30Hz and 35Hz), set 30Hz in Pr. 33 and 35Hz in Pr. 34.
To jump to 35Hz between 30 and 35Hz, set 35Hz in
Pr. 33 and 30Hz in Pr. 34.
CAUTION
During acceleration/deceleration, the running frequency within the set area is
valid.
REMARKS
Write disable error "
Factory
Setting
Setting
Range
0
Pr.36
Pr.35
Pr.34
Pr.33
Pr.32
Pr.31
Factory
Setting Range
Setting
---
---
---
---
---
---
" occurs if the frequency jump setting ranges overlap.
80
0: Without display,
0, 1
1: With display
to Pr. 36
Frequency jump
1B
1A
0 to 120Hz,---
0 to 120Hz,---
• - - -: Function invalid
0 to 120Hz,---
•Setting is enabled when Pr.
0 to 120Hz,---
30 = "1"
0 to 120Hz,---
0 to 120Hz,---
Pr.34:35Hz
Pr.33:30Hz
Pr.33:35Hz
Pr.34:30Hz
)
Remarks
)
3B
3A
2B
2A
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-s520e-0.1kFr-s540e-0.4kFr-s510we-0.1k