Mitsubishi FR-S500 Instruction Manual page 17

Transistorized inverter 3.7k-na / 0.75k-na
Hide thumbs Also See for FR-S500:
Table of Contents

Advertisement

Main circuit terminals
3) Single-phase 100V power input
FR-S510WE-0.1K, 0.2K, 0.4K-NA
FR-S510WE-0.75K-NA
N/-
P/+
N/-
P/+
U
V
W
R/L1
S/L2
U
V
W
R/L1 S/L2
IM
IM
Motor
Power supply
Motor
Power supply
CAUTION
Make sure the power cables are connected to the R/L1, S/L2, T/L3 of the inverter.
Never connect the power cable to the U, V, W of the inverter. (Phase need not be
matched)
Connect the motor to U, V, W. At this time, turning on the forward rotation switch
(signal) rotates the motor in the counterclockwise direction when viewed from the
motor shaft.
1