Explanation of functions (parameters)
2.3.4
Multi-speed operation (Pr. 4
Pr. 24
Used to switch between the predetermined running speeds.
Any speed can be selected by merely switching on/off the corresponding
contact signals (RH, RM, RL, REX signals).
By using these functions with Pr. 1 "maximum frequency" and Pr. 2 "minimum
frequency", up to 17 speeds can be set.
This function is valid in the external operation mode or in the combined
operation mode which is available when Pr. 79 = "3" or "4".
Speed 1
(high speed)
Speed 2
(middle speed)
Speed 3
(low speed)
ON
RH
ON
RM
ON
RL
Priority: RL>RM>RH
REX
Parameter
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
Multi-speed setting
24 to 27
(speeds 4 to 7)
Multi-speed setting
80 to 87
(speeds 8 to 15)
<Setting>
Set the running frequencies in the corresponding parameters.
Each speed (frequency) can be set as desired between 0 and 120Hz during inverter
operation.
When the parameter of any multi-speed setting is read, turn the
setting.
In this case, press the
the external mode.)
The setting is reflected by pressing the
Assign the terminals used for signals RH, RM, RL and REX using Pr. 60 to Pr. 63.
(When terminal assignment is changed using Pr. 60 to Pr. 63, the other functions may
be affected. Please make setting after confirming the function of each terminal.)
to Pr. 27
Speed 5
Speed 6
Speed 4
Speed 7
ON ON ON
ON
ON
ON
ON
ON
Factory
Name
Setting
60Hz
30Hz
10Hz
- - -
- - -
SET
(
WRITE
, Pr. 5
, Pr. 80
Speed 10
Speed 9
Speed 8
Time
RH
RM
ON
RL
ON
ON
REX
Setting
Range
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 120Hz,
- - -
0 to 120Hz,
- - -
) to store the frequency. (This is also enabled in
SET
(
).
WRITE
66
, Pr. 6
to Pr. 87
Speed 11
Speed 12
Speed 13
Speed 14
Speed 15
ON ON ON ON
ON ON
ON ON
ON
ON
ON
ON ON ON ON ON ON
Remarks
"- - -" = no setting. Setting
enabled when Pr. 30 = "1".
"- - -" = no setting. Setting
enabled when Pr. 30 = "1".
to change the
,
)
Time