Installing External Refractories - Heatilator ICON60IT Owner's Manual

Table of Contents

Advertisement

J. Installing External Refractories
Open Refractory Package
1 - LH side refractory panel
1 - RH side refractory panel
1 - Front hearth refractory panel
Notches indicate
top of refractory
Front Hearth
Figure 12.11 Refractory Pieces
Install Side Refractories
Locate right side refractory panel. See Figure 12.11.
Install rod in hole in glass frame top. See Figure 12.12.
Install rod with swedge (Figure 12.13) in hole in glass
frame bottom. See Figure 12.14.
Repeat for the left side refractory panel.
Insert Pin
Figure 12.12 Insert Pin into Top Frame
Swedge
Figure 12.13 Swedge
(Figure 12.11)
Right
Left
Notch
Heatilator • ICON DV • 4042-300 Rev R • 06/07
Insert Pin
Figure 12.14 Insert Pin into Bottom Frame
Bottom Front Hearth Refractory
Slide hearth refractory under side refractories until tight
against glass. See Figure 12.15.
Figure 12.15 Placing Bottom Front Hearth Refractory
Figure 12.16 Finished Refractory Installation
Swedge
39