Advertisement

* GRN wire only used
with optional wall switch
WSK-MLT-HTL
Wall Switch
GRN*
Figure 10.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram
WARNING
Shock Risk
Replace damaged wire with type 105° C
rated wire.
Wire must have high temperature
insulation.
32
Battery
Pack
-
+
+
RED
WHT
Heatilator • ICON DV • 4042-300 Rev R • 06/07
Control
To
Box
Junction
-
Box
3V
Adapter
BLK
RED
BRN
ORG
GRN
Valve
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Ignitor
Flame
Sensor
WHT
ORG
Pilot Assembly
BLK
CAUTION