Vent Clearances and Framing

A. Pipe Clearances to Combustibles
3 in.
(76 mm)
Sheetrock
2 x 4 or
2 x 6
header
Figure 6.1
Pipe Clearances
B. Wall Penetration Framing
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The
heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to
184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat
shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184
mm) a DVP-HSM-B will be required.
3 in. (76 mm)
top clearance
1 in. (25 mm)clearance
1 in. (25 mm)
bottom & sides
clearance
around vertical
sections
Figure 6.2
Horizontal Venting Clearances to Combustible Materi-
als
No combustible
framing to be
located within
shaded area.
1-1/2 in.
(38 mm)
3 in. (76 mm)
top clearance
Heat
Heat
Shield
Shield
1 in. (25 mm)
clearance
bottom & sides
Wall
Shield
Firestop
WALL
Heatilator • ICON DV • 4042-300 Rev R • 06/07
WARNING
Fire Risk
Explosion Risk
Maintain vent clearance to combustibles as
specifi ed.
Do not pack air space with insulation or
other materials.
Failure to keep insulation or other materials
away from vent pipe may cause fi re.
12 in.
The center of the
framing hole is
1 in. (25mm) above
the center of the
horizontal vent pipe.
Framing should be
constructed of 2 X 4
lumber or heavier.
Appliance
ICON60IT
ICON60ILT
ICON60IH
ICON60ILH
ICON100IT
ICON100ILT
ICON100IH
ICON100ILH
Figure 6.3
Exterior Wall Hole
Frame a hole in a combustible wall for a wall shield fi restop
(Figures 6.1 through 6.3) whenever a wall is penetrated.
Use same size framing materials as those used in the wall
construction. The wall shield fi restop maintains minimum
clearances and prevents cold air infi ltration.
If the hole being penetrated is surrounded by non-
combustible materials such as concrete, a hole with
diameter 1 in. greater than the pipe is acceptable.
10 in.
Vent framing hole.
DO NOT PACK WITH
INSULATION OR
OTHER MATERIAL.
A*
* Measured to
center of pipe.
A
64-1/8 in./1629 mm
64-1/8 in./1629 mm
64-1/8 in./1629 mm
64-1/8 in./1629 mm
68-5/8 in./1743 mm
68-5/8 in./1743 mm
68-5/8 in./1743 mm
68-5/8 in./1743 mm
19