Installing Vent Pipe; Assemble Vent Sections (Dvp Only) - Heatilator Novus NDV Series Owner's Manual

Table of Contents

Advertisement

10 10

Installing Vent Pipe

A. Assemble Vent Sections (DVP only)
Attach Vent to the Firebox Assembly
Note: The end of the pipe sections with the lanced tabs will face
toward the appliance.
Attach the fi rst pipe section to the starting collar:
Lanced pipe end of the starting collar
Inner pipe over inner collar
Push the pipe section until all lanced tabs snap in place
Lightly tug on pipe to confi rm it has locked.
Commercial, Multi-family (Multi-level exceeding two
stories), or High-Rise Applications
All outer pipe joints must be sealed with high temperature
silicone (300º F minimum continuous exposure rating), in-
cluding the slip section that connects directly to the hori-
zontal termination cap.
Apply a bead of silicone sealant
continuous exposure rating)
joint prior to joining sections. See Figure 10.1
Only outer pipes must be sealed. All unit collar, pipe,
slip section, elbow and cap outer fl ues shall be sealed
in this manner, unless otherwise stated.
WARNING! Risk of Fire/Explosion! DO NOT break
silicone seals on slip sections. Use care when removing
termination cap from slip pipe. If slip section seals are
broken during removal of the termination cap, vent will
leak and a fi re or explosion could occur.
Assemble Pipe Sections
See Figure 10.2.
Start the inner pipe on the lanced end of section A into
the fl ared end of section B.
Start the outer pipe of section A over the outer pipe of
section B.
Once both vents sections are started, push fi rmly until
all lanced tabs lock into place.
Lightly tug on the pipe to confi rm the tabs have locked.
It is acceptable to use screws no longer than 1/2 in. (13 mm)
to hold outer pipe sections together. If predrilling holes, DO
NOT penetrate inner pipe.
For 90° and 45° elbows that are changing the vent direction
from horizontal to vertical, one screw minimum should be
put in the outer fl ue at the horizontal elbow joint to prevent
the elbow from rotating. Use screws no longer than 1/2 in.
(13 mm). If predrilling screw holes, DO NOT penetrate in-
ner pipe.
40
All manuals and user guides at all-guides.com
(300º F minimum
inside the female outer pipe
Heatilator • Novus NDV Series • 4055-187 Rev. AA • 10/13
Figure 10.1 High Temperature Silicone Sealant
A
B
Figure 10.2
Note:
Make sure that the seams are not aligned to prevent
unintentional disconnection.
CORRECT
INCORRECT
Figure 10.4 Seams
A
B
Figure 10.3