CC484/CC486/CC488 | Operators Manual | 3.
3.1

Zone Indicators

The zone indicators (1 to 8) display
1 2 3 ....
the status of the zones. Table 2 lists the
various circumstances that the
indicators display (such as Zone
Sealed, Zone Unsealed, and so on).
Table 2:
Zone Indicators
Indicator
On
Off
Flashing Fast
(0.25 seconds on/
0.25 seconds off)
Flashing Slow
(1 second on/
1 second off)
3.2

AWAY Indicator

The AWAY indicator displays that the
system is armed in AWAY Mode. The
AWAY indicator flashes in unison with
the STAY indicator when
programming various options
throughout the Operators Manual.
See Section 3.10.2 Arming in AWAY Mode
for information on the different
methods of arming the system in
AWAY Mode.
Table 3:
AWAY Indicator
Indicator
Definition
On
System is armed in AWAY Mode.
Off
System is not armed in AWAY Mode.
3.3

STAY Indicator

The STAY indicator displays that the
system is armed in STAY Mode 1 or
STAY Mode 2. The STAY indicator also
flashes in unison with the AWAY
indicator when programming various
options throughout the Operators Manual.
See Section 3.10.3 Arming in STAY Mode 1
for different methods of arming in STAY
Mode 1. See Section 3.10.4 Arming in
STAY Mode 2 for the method of arming in
STAY Mode 2.
Bosch Security Systems | 3/04 | SUB-MA48XO-3318
Definition
Zone is unsealed.
Zone is sealed.
Zone is in alarm condition.
Zone is manually isolated or
selected to be isolated.
Codepad Indicators
Table 4:
STAY Indicator
Indicator
Definition
On
System is armed in STAY Mode 1
or STAY Mode 2.
Off
System is not armed in STAY
Mode 1 or STAY Mode 2.
Flashing
Zone isolating mode or setting
twice a
STAY Mode 2 zones.
second
Flashing once
Day alarm status – day alarm
every
turned on.
3 seconds
3.4

System Disarmed

This indicator displays with the
indicator when the system is disarmed.
3.5

MAINS Indicator

The MAINS indicator displays that the
system's AC mains supply is normal or
failed.
Table 5:
MAINS Indicator
Indicator
On
Flashing
3.6

Off Indicator/Zone Sealed

The
system is in the disarmed state and
flashes when a zone becomes unsealed
during the disarmed state. The
indicator stops flashing when all zones
are sealed.
3.7

On Indicator/Zone In Alarm

The
system is armed in AWAY Mode and
flashes when an alarm occurs. The
indicator resets once a valid user code
is entered.
Definition
AC mains power normal.
AC mains supply has failed.
indicator displays when the
indicator displays when the
EN | 6