CC484/CC486/CC488 | Operators Manual | 9. Fault Analysis Mode

Table 11: Fault Indicators

Zone Indicator
Fault Description
1
System Fault
2
RF Low Battery
3
Zone Tamper Alarm
4
Sensor Watch Fault
5
RF Sensor Watch
6
Communication Fail
9.1

Fault Descriptions

1
System Fault
A system fault only displays when any of
the following faults occur. After entering
Fault Analysis Mode, press and hold the
[1] key to determine which of the
following faults occurred.
Low Battery Fault – A low battery fault
registers when the system detects a low
capacity back-up battery. The system
automatically performs a battery test
every four hours and every time you arm
the system.
Date and Time – The date and time fault
registers every time the system is powered
down. This type of fault does not cause
the FAULT indicator to display on the
codepad unless your installer
programmed the automatic arming time.
See Section 10. Date and Time to program
the date and time.
RF Receiver Fail – The RF receiver fault
registers once the system detects that the
wireless receiver unit is disconnected.
Horn Speaker Fail – This fault registers
when the system detects that the horn
speaker is disconnected. This fault clears
once the horn speaker is reconnected.
Your installer must program the system
for this feature to operate.
Bosch Security Systems | 3/04 | SUB-MA48XO-3318
Hold Down Button
Zone Indicator
1
2
3
4
5
6
2
3
Fault Condition
1
Battery Fail
2
Date and Time
3
RF Receiver Fail
4
Horn Speaker Fail
5
Telephone Line Fail
6
E2 Fault
7
Fuse Fail
8
AC Fail
1 to 8
Zones 1 to 8 RF Low Battery
1 to 8
Zones 1 to 8 Tamper Alarm
1 to 8
Zones 1 to 8 Sensor Watch Fail
1 to 8
Zones 1 to 8 RF Sensor Watch Fail
1
Receiver 1 Fail
2
Receiver 2 Fail
Telephone Line Fail – A telephone line
fault registers when the system detects
that the telephone line is disconnected
from the control panel. Your installer
must program the system for this feature
to operate.
E2 Fault – An E2 fault registers when the
system detects an internal checksum
error. Contact your installer as soon as
this fault displays.
Fuse Fail – This fault occurs when either
of the two 1 A fuses blow. Contact your
installer as soon as this fault displays.
RF Low Battery
This fault occurs when any of the RF
wireless devices report a low battery
condition to the control panel. While in
Fault Analysis Mode, press and hold the
[2] key until two beeps sound. This
displays the zone reporting the RF Low
Battery fault.
Tamper Fail
This fault occurs when any zone becomes
an open circuit. Press and hold the [3]
key until two beeps sound. This displays
the zone reporting the tamper fail fault.
EN | 12