Image Is Blurred; The Leading Edge Of The Image Is Consistently Misaligned With The Original; The Leading Edge Of The Image Is Sporadically Misaligned With The Original; Paper Creases - Olivetti d-copia 1800 Service Manual

Hide thumbs Also See for d-copia 1800:
Table of Contents

Advertisement

(10) Image is blurred.

Copy example
Scanner moves erratically.
Deformed press roller.
Paper conveying section drive prob-
lem.

(11) The leading edge of the image is consistently misaligned with the original.

Copy example
Misadjusted leading edge registration. Run maintenance mode U034 to readjust the leading edge
Misadjusted scanner leading edge
registration.

(12) The leading edge of the image is sporadically misaligned with the original.

Copy example
Paper feed clutch, MP solenoid or
registration clutch installed or operat-
ing incorrectly.

(13) Paper creases.

Copy example
Paper curled.
Paper damp.
Defective pressure springs.
Defective separation.
Y110980-1
Causes
Causes
Causes
Causes
Service Manual
Check procedures/corrective measures
Check if there is any foreign matter on the front and rear
scanner rails. If any, remove it.
Replace the press roller (see page 1-5-42).
Check the gears and belts and, if necessary, grease them.
Check procedures/corrective measures
registration (see page 1-3-12).
Run maintenance mode U066 to readjust the scanner lead-
ing edge registration (see page 1-3-20).
Check procedures/corrective measures
Check the installation position and operation of each clutch
or solenoid. If any of them operates incorrectly, replace it.
Check procedures/corrective measures
Check the paper storage conditions.
Check the paper storage conditions.
Replace the pressure springs.
Check the drum separation claws and heat roller separation
claws.
2KL/2KK