MOUNTING

1.1

Mounting Considerations

TZT9
When selecting a mounting location for TZT9/14, keep the following in mind:
• The temperature at the mounting location shall be between -15°C and +55°C (wire-
less LAN: 0°C and +55°C).
• The humidity at the mounting location shall be 93% or less at 40°C.
• Locate the unit away from exhaust pipes and ventilators.
• The mounting location should be well ventilated.
• Mount the unit where shock and vibration are minimal (comply with IEC 60945
Ed.4).
• Keep the unit away from electromagnetic field generating equipment such as mo-
tors and generators.
• For maintenance and checking purposes, leave sufficient space around the unit and
leave slack in cables. Minimum recommended space is shown in the outline draw-
ing for the display units.
• Do not mount the TZT9/14 on the overhead.
• A magnetic compass will be affected if the equipment is placed too close to it. Ob-
serve the compass safe distances shown in the SAFETY INSTRUCTIONS to pre-
vent disturbance to the magnetic compass.
The TZT9/14 can be flush mounted in a console or panel, or mounted on a desktop.
When removing the equipment
If the equipment is removed from the vessel, cover the connector of the cable with the
supplied cap to keep dust out of the connector.