1.

MOUNTING

1.1

Installation of Multi Function Display

The TZT12F is designed to be mounted in a console or panel, or mounted on a desk-
top.
The installer of this equipment must read and follow the descriptions in this manual.
Wrong installation or maintenance can void the warranty.
Mounting considerations
When selecting a mounting location for your TZT12F, keep the following in mind:
• The temperature at the mounting location shall be between -15°C and +55°C.
• The humidity at the mounting location shall be 93% or less at 40°C.
• Locate the unit away from exhaust pipes and ventilators.
• The mounting location should be well ventilated.
• Mount the unit where shock and vibration are minimal (compliant with IEC 60945
Ed.4).
• Keep the unit away from electromagnetic field generating equipment such as
motors and generators.
• For maintenance and checking purposes, leave sufficient space around the unit and
leave slack in cables. Minimum recommended space is shown in the outline
drawing for the display units.
• Do not mount the unit on an overhead beam/bulkhead.
• A magnetic compass will be affected if the equipment is placed too close to it.
Observe the compass safe distances shown in the SAFETY INSTRUCTIONS to
prevent disturbance to the magnetic compass.
1.1.1
How to install the multi function display
Referring to the figure below, select a flat mounting location. Read the installation in-
structions before starting. Pay particular attention to the notes; failure to follow these
instructions may cause damage to the unit.
Note: Ensure the mounting location is flat, with no indents or protrusions, to allow a
secure fit.
1. Prepare a cutout in the mounting location using the template (supplied) for the
TZT12F.
Flat
Curved
Bumpy
1-1