Toshiba e-STUDIO2330C Service Handbook page 378

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO2330C:
Table of Contents

Advertisement

[CEC0] 2nd transfer roller position detection abnormality
Is the 2nd transfer roller contacted and released properly? (Perform the output check: 03-239)
|
NO
|
|
|
|
|
|
|
|
|
YES
Is the 2nd transfer roller position detection sensor(S29) working properly?
(Perform the input check:03-[FAX]ON/[2]/[F])
|
NO
|
|
|
|
|
|
|
|
|
YES
1. Check if there is any abnormality with the mechanical section (sensor's actuator, etc.).
2. Check if the conductor pattern on the LGC board is short circuited or open circuited.
3. Replace the LGC board.
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
ERROR CODE AND TROUBLESHOOTING
1. Check if the connectors of the registration motor(M19) are disconnected.
2. Check if the connector CN332 on the LGC board is disconnected.
3. Check if the connector pins are disconnected or the wires of harnesses are
open circuited.
4. Check if the conductor pattern on the LGC board is short circuited or open
circuited.
5. Replace the registration motor.
6. Replace the LGC board.
1. Check if the connector or joint connectors of the 2nd transfer roller position
detection sensor are disconnected.
2. Check if the connector CN337 on the LGC board is disconnected.
3. Check if the connector pins are disconnected or the wires of harnesses are
open circuited.
4. Check if the conductor pattern on the LGC board is short circuited or open
circuited.
5. Replace the 2nd transfer roller position detection sensor.
6. Replace the LGC board.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
6 - 102

Hide quick links:

Advertisement

Table of Contents
loading