Bosch DCN Next Generation Installation And User Instructions Manual page 46

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN NG | Installation and User Instructions | Section 2 | Interpretation Equipment
5.5.3
Auto increment/decrement
volume (X12)
The auto increment/decrement volume function of the
channel selector can be configured using solder spot
X12 (see figure 5.9).
table 5.6: Solder spot X12
Solder spot
Description
Open
The auto increment/decrement
(default)
volume function is enabled. As
long as the volume up (down) key
is pressed, the volume is increased
(decreased) until the maximum
(minimum) volume has been
reached. The volume is
incremented (decremented) at a
rate of 12 dB per second when
holding the volume up (down) key
for longer than 0.25 seconds.
Closed
The auto increment/decrement
volume function of the channel
selector is disabled. When the
volume up (down) key is pressed,
the volume is increased
(decreased) with a single step of
1 dB.
Bosch Security Systems | 2004-03 | 9922 141 70521en
5.5.4
Auto restore function (X13)
The auto restore function of the channel selector can be
configured using solder spot X13 (see figure 5.9). The
auto restore function is intended for users that have a
fixed seating.
table 5.7: Solder spot X13
Solder spot
Description
Open
The auto restore function is
(default)
disabled. When the system is
switched on and the channel
selector is activated, the default
volume and channel settings are
restored (channel: 0, volume:
-21 dB).
Closed
The auto restore function is
enabled. When the system is
switched on or the channel
selector is activated, the last
known volume and channel
settings are restored.
Note
Any changes in channel or volume settings are
saved after 5 seconds.
Note
If the stored channel number is greater than the
maximum number of channels available, the
selector automatically chooses channel 0.
However, if the number of channel available is
increased and the stored channel number is less
or equal to the maximum numbers available and
if the channel control keys are not pressed in the
mean time, the channel selector immediately
switches to the stored channel.
Note
If the channel selector is used for recording
purposes, the X13 solder spot must be closed.
en | 46

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents