DCN NG | Installation and User Instructions | Section 4 | Installation Accessories
13.4

Custom-made cables

See table 13.2 and section 13.3 for information about
creating customized cable connections.
table 13.2: DCN cable connectors
Connector
Hirschmann
type no.
Cable-plug
MAS 6100
(black) with
locking screw
(male)
Cable-plug
MAS 60
(black) with
locking screw
(male)
Cable socket
MAK 6100
with locking
screw (female)
Note
MAS 6100 cannot be used in the trunk splitter
(LBB4114/00) and tap-off unit (LBB4115/00)
due to the length of the cap.
Note
The screening of the cable is connected to the
earth tags of the Hirschmann cable plug/socket
and is potentially live. Therefore, only use
isolated sockets for extension cables, patch
panels and floor boxes.
When connecting connectors to extension cables, it is
recommended that insulated, metal shield connectors
are used, rather than plastic shield connectors to protect
the connectors according to EMC specifications.
Bosch Security Systems | 2004-03 | 9922 141 70521en
Service code no.
5322 264 54055
4822 264 40024
5322 264 10367
en | 104