3.1 Parallel Ports
3.1.1 Wiring to the Terminal Blocks
Output terminal block
Terminal block for power supply input
About terminal block
The PV310 is equipped with the attachable input/output terminal blocks. Use fittings and cables show in the
tables below.
Terminal block
Manufacturer
socket
Phoenix Contact
Tightening
Manufacturer
fittings
Phoenix Contact
Acceptable Wire
Size
(Twisted wire)
AWG#24 to 26
How to Wire
1
Remove the wire shield.
28
Model No.
Input
MC1.5/18-ST-3.5
Output
MC1.5/16-ST-3.5
Model No.
Conductor surface area
(cross-section)
SZ 0.4 x 2.5
0.4 x 2.5 mm
Conductor surface area (cross-section)
0.3 to 1.25 mm
2
Insert the wire into a
terminal block hole until it
stops and screw it down.
Product No.
1840528
1840502
Tightening torque
2
Less than 0.25 N•m
2
3
When connecting multiple
wires, twist them together
before inserting.