7.4 Statistics (QS01 to QS96)

7.4.1 Main Functions

Counting Number of OK/NG Judgments and Analyzing OK Judgment Results
As for up to 96 items of the referred formulas and judgment results, the PV310 counts the number of OK/NG
judgment results. Counting the number of OK/NG judgment results starts after the PV310 was turned on. The
counted results can be reset to 0 by turning off the PV310, changing the product types or forcibly resetting the
results. In addition, the calculation results such as the following data, which were judged as OK, are saved.
Average value
Variance value
Max.
Min.
Range (difference between Max. and Min.)
Counting Scanning Number
The number of inspections is counted after the PV310 was turned on. The counted number is returned to "0" by
turning off the PV310, switching the product types or forcibly resetting the system.

7.4.2 Reference Data

A List of the Data Can Be Referred to Statistics
The following data can be referred to Statistics.
Reference Data
Judgment
Numeric Calculation
You cannot refer the data of Judgment and Numeric Calculations that you have set to output to the Statistics
table.
Symbol
Number
Details
JD
01 to 96
Counts only the number of OK/NG judgment results
CA
01 to 96
Counts all items.
189