Panasonic MICRO-IMAGECHECKER PV310 Use Manual page 228

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

Item
Data
Output
Output
Digits
Settings
Unused
Digits
Type
Switch
Signal
Register
number for
Type
number
PLC
Model
Start
Register
Timeout
(ms)
Data Type
Handshak
e
Data Type
Delay
Time
Timeout
Serial
Command -
Commun
Format
ication
Command -
Unused Digits
RS232C
220
Option
(Initial value: With
Function
an underline)
1 to 11
To specify the digit number of output data.
Comma
To set a process when the output digit number is less
separated/Filled
than output digit number.
with '0'
Parallel / Computer
To select parallel I/O or reference data stored in the
Link
specified register to input a type switch signal in
Computer Link mode.
(Only when the Output Setting is set to "Computer
Link".)
0 to 9999
To specify the register number to store the number of
type switch signal that is input through Computer Link.
(Only when the Type Switch Signal is set to "Computer
Link".)
Panasonic FP/
Sets a PLC type for communicating in Computer Link
MELSEC A+Q/
communication mode.
MELSEC FX/
(Only when the Output Setting is set to "Computer
OMRON C + CV +
Link".)
CS1 / AB SLC /
MICREX SX
0 to 9999
Specifies the top number of the target PLC data
register to which data are output (available only if
Output Setting = Computer Link).
0 to 20000 ms
To limit the response time from PLC (available only if
(Initial value:5000)
Output Setting = Computer Link)
16-bit/ 32-bit
To specify an output data length in the Computer Link
communication mode.
No/Yes
No: 8 Judgment formulas JD01 to JD08 are output to
an external device.
Yes: The PV310 outputs the items (Scan, Judgment,
Num. Calcu., and Statistics) that have been set to
output to the external device
8 bit/16 bit/32 bit
To set output data length (available only if Output
Setting = Computer Link)
300 to 20000 μs
To set the interval of image output.
(Initial value: 5000)
0 to 20000 ms
To limit the response time (up to ACK signal receive)
(Initial value: 300)
from PLC during handshake
Comma separated
To Insert a comma to separate between the items.
This function does not fix the number of digits of the
items in the commands.
Fixed Length
To fix the number of digits all the items in the
commands to four digits.
Filled with 'Blanks'
Format: For less than 4-digit command, select whether
/ Filled with '0'
the command is replaced with a space or "0" when
"Format" is set to "Fixed Length".
Baud Rate (bps),
Select a condition for RS-232C communication with
Bit Length, Stop
the external device
Bit, Parity, Flow
Control
Ref.
page
259
288
283
242
247
259
260