Sign In
Upload
Manuals
Brands
Riello Manuals
Burner
RS 500/EV BLU
Riello RS 500/EV BLU Manuals
Manuals and User Guides for Riello RS 500/EV BLU. We have
2
Riello RS 500/EV BLU manuals available for free PDF download: Installation, Use And Maintenance Instructions
Riello RS 500/EV BLU Installation, Use And Maintenance Instructions (52 pages)
Forced draught gas burners
Brand:
Riello
| Category:
Burner
| Size: 1.63 MB
Table of Contents
Table of Contents
3
Declarations
5
Information and General Warnings
6
Information about the Instruction Manual
6
Introduction
6
General Dangers
6
Other Symbols
6
Delivery of the System and the Instruction Manual
7
Guarantee and Responsibility
7
Safety and Prevention
8
Introduction
8
Personnel Training
8
Technical Description of the Burner
9
Burner Designation
9
Models Available
9
Technical Data
10
Electrical Data
10
Burner Categories - Countries of Destination
11
Maximum Dimensions
11
Firing Rates
12
Test Boiler
13
Burner Equipment
13
Burner Description
14
Electrical Panel Description
15
Control Box for the Air/Fuel Ratio (LMV52
16
Servomotor (SQM48.4
18
Installation
19
Notes on Safety for the Installation
19
Handling
19
Preliminary Checks
19
Operating Position
20
Removal of the Locking Screws from the Shutter
20
Preparing the Boiler
20
Boring the Boiler Plate
20
Blast Tube Length
20
Securing the Burner to the Boiler
21
Access to Head Internal Part
21
Probe-Electrode Position
21
Combustion Head Adjustment
22
Gas Feeding
23
5.11.1 Gas Feeding Line
23
5.11.2 Gas Train
24
5.11.3 Gas Train Installation
24
5.11.4 Gas Pressure
25
Electrical Wiring
26
Supply Cables and External Connections Passage
26
Start-Up, Calibration and Operation of the Burner
27
Notes on Safety for the First Start-Up
27
Adjustments Prior to Ignition
27
Burner Start-Up
27
Burner Ignition
27
Combustion Air Adjustment
28
Air Adjustment for Maximum Output
28
Air/Fuel Adjustment and Output Modulation System
28
Pressure Switch Adjustment
29
Air Pressure Switch - Check CO
29
Maximum Gas Pressure Switch
29
Minimum Gas Pressure Switch
29
PVP Pressure Switch Kit
29
Maintenance
30
Notes on Safety for the Maintenance
30
Maintenance Programme
30
Maintenance Frequency
30
Checking and Cleaning
30
Positioning the Revolution Sensor
31
Opening the Burner
32
Closing the Burner
32
Faults - Probable Causes - Solutions
33
Appendix - Accessories
34
Appendix - Electrical Panel Layout
36
Advertisement
Riello RS 500/EV BLU Installation, Use And Maintenance Instructions (48 pages)
Forced draught gas burners
Brand:
Riello
| Category:
Burner
| Size: 1.97 MB
Table of Contents
Table of Contents
3
1 Declarations
5
2 Information and General Warnings
6
Information about the Instruction Manual
6
Introduction
6
General Dangers
6
Other Symbols
6
Delivery of the System and the Instruction Manual
7
Guarantee and Responsibility
7
3 Safety and Prevention
8
Introduction
8
Personnel Training
8
4 Technical Description of the Burner
9
Burner Designation
9
Models Available
9
Technical Data
10
Electrical Data
10
Burner Categories - Countries of Destination
11
Maximum Dimensions
11
Firing Rates
12
Test Boiler
13
Burner Equipment
13
Burner Description
14
Electrical Panel Description
15
Air/Fuel Ratio Control Apparatus (ETAMATIC OEM)
16
4.13 Display
18
Flame Sensor FFS 06
18
Servomotors
19
5 Installation
20
Notes on Safety for the Installation
20
Handling
20
Preliminary Checks
20
Operating Position
21
Removing the Shutter Lockout Screws
21
Preparing the Boiler
21
Boring the Boiler Plate
21
Blast Tube Length
21
Securing the Burner to the Boiler
22
Access to Head Internal Part
22
Probe-Electrode Position
22
Combustion Head Adjustment
23
Gas Feeding
24
5.11.1 Gas Feeding Line
24
5.11.2 Gas Train
25
5.11.3 Gas Train Installation
25
Gas Pressure
26
Electrical Wiring
27
Supply Cables and External Connections Passage
27
6 Start-Up, Calibration and Operation of the Burner
28
Notes on Safety for the First Start-Up
28
Adjustments Prior to Ignition
28
Burner Start-Up
28
Burner Ignition
28
Combustion Air Adjustment
29
Air Adjustment for Maximum Output
29
Air/Fuel Adjustment and Output Modulation System
29
Pressure Switch Adjustment
30
Air Pressure Switch - Check CO
30
Maximum Gas Pressure Switch
30
Minimum Gas Pressure Switch
30
PVP Pressure Switch Kit
30
7 Maintenance
31
Notes on Safety for the Maintenance
31
Maintenance Programme
31
Maintenance Frequency
31
Checking and Cleaning
31
Safety Components
32
Opening the Burner
32
Closing the Burner
32
8 Faults - Possible Causes - Solutions
33
Appendix - Accessories
34
Appendix - Electrical Panel Layout
36
Advertisement
Related Products
Riello RS 500/E BLU
Riello RS 500/M BLU
Riello RS 500/EV FGR
Riello RS 50/M MZ
Riello RS 50/EV
Riello RS 50/E
Riello RS 510/E ULX
Riello RS 510/EV O2 ULX
Riello RS 510/E O2 ULX
Riello RS 510/EV MZ
Riello Categories
Burner
Boiler
Indoor Fireplace
UPS
Water Heater
More Riello Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL