Sign In
Upload
Manuals
Brands
Pressure Systems Manuals
Scanner
9016
Pressure Systems 9016 Manuals
Manuals and User Guides for Pressure Systems 9016. We have
2
Pressure Systems 9016 manuals available for free PDF download: User Manual, Upgrade Instructions
Pressure Systems 9016 User Manual (194 pages)
NetScanner System Intelligent Pressure Scanner
Brand:
Pressure Systems
| Category:
Scanner
| Size: 7.29 MB
Table of Contents
Technical Support
5
Table of Contents
7
Chapter 1 - General Information
12
Introduction
12
Description of Instruments
14
Options
15
Pressure Ranges
15
Manifolds and Pressure Connections
15
Communication Interfaces
16
Chapter 2 - Installation and Set up
18
Unpacking and Inspection
18
Safety Considerations
18
Preparation for Use
19
Environment
19
Power
19
Figure 2.1 9016, 9021, 9022 Power Pin Assignments
19
Mounting and Module Dimensions
20
Network Communications Hookup
20
Ethernet Host Port Hookup
20
Ethernet Host Port Connector Pins
20
Figure 2.3 Ethernet Network Topology
23
Diagnostic Port Hookup
24
Pressure Connections
24
Table 2.1 Diagnostic Port Wiring
24
RUN Mode Inputs
25
CAL Mode Inputs
26
Purge Mode Inputs
26
Leak Mode Inputs
27
Supply Air
27
9021 And 9022 Transducer Installation
28
Installation of 9400, 9401 and 9402 Transducers
28
Installation of All Other Transducers
29
9021 Transducer Wiring
29
Figure 2.4 9021 Transducer Wiring
29
Figure 2.4A 9022 Transducer Wiring
29
Case Grounding
30
Power up Checks and Self-Diagnosis
30
Trigger Input Signal
30
Chapter 3 - Programming and Operation
31
Commands and Responses
31
Introduction
31
TCP/UDP/IP Protocols
31
Commands
32
General Command Format
32
Command Field
33
Position Field
33
Datum Fields
34
Format Field
35
Responses
35
Interpreting Offset Values (Re-Zero Calibration Adjustment)
36
Table 3.1 Error Codes
36
Interpreting Gain Values (Span Calibration Adjustment)
37
Interpreting Engineering Unit Output
37
Functional Command Overview
37
Startup Initialization
37
Module Data Acquisition
39
Calibration Adjustment of Offset/Gain
39
Correction Coefficients
39
Delivery of Data to Host
41
Network Query and Control Functions
41
Other Functions
42
Detailed Command Description Reference
43
Table 3.2 Intelligent Pressure Scanner Commands
43
Power up Clear
44
Reset
45
Configure/Control Multi-Point Calibration
46
Read Transducer Voltages
54
Calculate and Set Gains
56
Read Transducer A/D Counts
58
Read High-Speed Data
60
Define/Control Autonomous Host Streams
61
Calculate and Set Offsets
79
Read Temperature Counts
81
Read Temperature Voltages
83
Read Module Status
85
Read High-Precision Data
88
Read Transducer Temperature
90
Read Internal Coefficients
92
Download Internal Coefficients
94
Network Query
105
Re-Boot Module
107
Obsolete Commands
109
Chapter 4 - Calibration
111
Introduction
111
Re-Zero Calibration
114
Re-Zero Calibration Valve Control
114
Re-Zero Calibration Summary
115
Span Calibration
116
Span Calibration Valve Control
117
Span Calibration Summary
118
Integrated Multi-Point Calibration Adjustment
120
Multi-Point Calibration Summary
121
9021/9022 Analog Calibration
123
Setup
124
Figure 4.5 9021 and 9022 Voltage Input Connections
124
Calibration Procedure
125
Coefficient Storage
129
Non-Volatile Parameter Storage for "Non-Digitally Compensated" Pressure Sensors
129
Line Pressure Precautions
134
Chapter 5 - Service
135
Maintenance
135
Figure 5.1 Exploded View of 9016 and 9022
135
Common Maintenance
137
Table 5.1 Component Cross Reference
137
Electronic Circuit Board Replacement
139
Figure 5.2 9016 Scanner out of Housing
139
Figure 5.2A 9022 Scanner out of Housing
139
Amplifier/Multiplexer Board
140
Amplifier/Multiplexer Board
141
Ethernet Microprocessor /A/D Board
141
Figure 5.3A 9022 Pcbs Outside the Housing
143
Figure 5.3B 9022 Pcbs Apart
143
Module Disassembly
139
Replacement of Transducers
144
Figure 5.4 Top View of DH200
145
Calibration Valve Solenoid Replacement
146
Figure 5.5 Solenoid in Module
146
Replacement of O-Rings
147
DH200 Pressure Transducer O-Ring Replacement
147
DH200 Transducer O-Ring Replacement
148
Tubing Plate O-Ring Replacement
149
Adapter Plate O-Ring Replacement
150
Calibration Manifold Piston O-Ring Replacement
151
Solenoid Valve O-Ring Replacement
152
Figure 5.7 Solenoid Valve O-Ring Replacement
152
9022 Excitation Trim
153
Figure 5.8 PC-317 Board (Trim Potentiometer and Jumper)
153
9022 Procedure for Changing the Excitation Jumper Setting (JB1)
154
Upgrading Module Firmware
155
Upgrading Firmware Via Host TCP/IP Port
155
Chapter 6 - Troubleshooting Guide
157
Ethernet Module Troubleshooting
157
Checking Module Power-Up Sequence
157
Checking Module TCP/IP Communications
158
Module IP Address Assignment
158
Host IP Address Assignment for Windows 95/98/NT
160
Verifying Host TCP/IP Communications
161
Zero and Gain Calibration Troubleshooting
162
User Software
165
Chapter 7 - Start-Up Software
166
Introduction
166
C Configure/Control Multi-Point Calibration
168
T Read Transducer Temperature
168
Advertisement
Pressure Systems 9016 Upgrade Instructions (13 pages)
NetScanner System Upgrade kit
Brand:
Pressure Systems
| Category:
Accessories
| Size: 1.23 MB
Advertisement
Related Products
Pressure Systems 9022
Pressure Systems NetScanner 9116
Pressure Systems 9046
Pressure Systems 9816
Pressure Systems 98RK-1
Pressure Systems 9021
Pressure Systems Ester9046
Pressure Systems Categories
Scanner
Accessories
More Pressure Systems Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL