Sign In
Upload
Manuals
Brands
KaVo Manuals
Medical Equipment
ORTHOPANTOMOGRAPH OP 3D Pro
KaVo ORTHOPANTOMOGRAPH OP 3D Pro Manuals
Manuals and User Guides for KaVo ORTHOPANTOMOGRAPH OP 3D Pro. We have
3
KaVo ORTHOPANTOMOGRAPH OP 3D Pro manuals available for free PDF download: Service Manual, Installation Manual, User Manual
KaVo ORTHOPANTOMOGRAPH OP 3D Pro Service Manual (192 pages)
3D Dental X-ray System
Brand:
KaVo
| Category:
Dental equipment
| Size: 7 MB
Table of Contents
Table of Contents
5
1 Introduction
9
ORTHOPANTOMOGRAPH™ OP 3D Pro
9
Intended Use
10
Associated Documentation
10
References
10
Abbreviations Used in this Manual
11
Warnings and Precautions
12
Warnings for Cross Infection
12
Warnings to be Observed During Installation and Service
12
Cautions for Electrostatic Discharge
14
General Warnings
14
Disclaimer
17
Disposal
17
2 Unit Description
19
Main Parts and Controls
19
Patient Positioning Lights
21
Patient Positioning Panel
25
Cephalometric Unit Positioning Panel
25
Main Control Panel
26
Unit Identification Labels
27
Unit Movements
28
Finger Guards
29
Emergency Stop Switch
30
3 Electrical Description
33
Circuit Boards
33
Electrical Component Location
35
List of Circuit Boards and Electric Devices
38
Schematic Diagrams
41
Circuit Board Descriptions
55
R3220 CPU (Central Processing Unit)
55
Ceph R3210
56
R3300 IO1 (Input/Output 1)
57
R3400 NGEO IO2 (Input/Output 2 Board)
58
R3710 X-Ray Power Supply
60
R3810 X-Ray Generator
61
R5100 3-Phase Stepper Driver
63
R5300 Panel Raw Power Supply
64
EA100 Power Distribution Board
65
EA200 Connector Board
67
EA300 Connector Board
69
EB100 Rotator Opto Board
69
EC100 Pan Sensor Connector Board
70
ED100 Pan Sensor Connector Board
71
ED200 Ceph Sensor Connector Board
72
EE100 Ceph Encoder Opto Board
73
EE200 Ceph Sensor Connector Board
74
EG100 Dual Opto Board
75
EG200 Interface Board
76
EG400 Panel Power Supply
78
Panoramic Sensor (CMOS)
79
Sensor (CMOS)
79
Ethernet Switch/Router
80
EC400 Collimator Opto Board
81
Replacing the Boards
82
4 Firmware Description
89
Overview
89
Detailed View
90
Operating Modes
91
Firmware States
92
5 Hardware Operation
97
Emergency Stop
97
Movements
98
Rotation Movement
98
X-Movement
99
Y-Movement
100
Z-Movement
101
Chin Rest Movement
102
Collimator Movement
103
Pan Sensor Movement
104
Secondary Collimator Movement
105
Ceph Sensor Movement
106
Imaging Chain
107
Panoramic Imaging Chain
108
Cephalometric Imaging Chain
109
Exposure Control
110
Exposure Warning Light
111
6 The S2Terminal and Service Functions
113
Opening the S2Terminal
114
S2Terminal Commands
115
Unit State Commands
117
Unit Service Commands
119
7 Error Codes and Troubleshooting
123
Initial Actions
123
Checking the Unit
123
Reporting Problems to Technical Support
126
Error Code Descriptions
130
Error 4 Rotator Home Position was Not Found
130
Error 5 Exposure was Taking too Long and a Timeout Occured
131
Error 6 Generator Failure
131
Error 9 R3300 IO1 Board Is Not Functioning
132
Error 12 R3400 IO2 Board Is Not Functioning
133
Error 13 Configuration Data was Lost
133
Error 21 Calibration Data Receive Timeout
134
Error 22 Reading Data from the 3D Sensor Failed
134
Error 23 Configuration Data Is Invalid
135
Error 24 Voltage (Kv) Failure in R3810 X-Ray Generator
135
Error 25 Current (Ma) Failure in R3810 X-Ray Generator
135
Error 26 Preheat Failure in R3810 X-Ray Generator
136
Error 27 Rotation Encoder Failure
136
Error 29 Error in Sensor Clocking Signal
136
Error 30 CPU Firmware Is Corrupted
137
Error 31 CPU Board's Memory Test Failed
137
Error 32 Movement of Z-Motor Failed
137
Error 33 Movement of C (Collimator) Motor Failed
138
Error 34 Movement of D (Sensor) Motor Failed
139
Error 35 Movement of J (Chin Support) Motor Failed
140
Error 36 Movement of N Motor Failed
141
Error 37 Movement of R (Rotation) Motor Failed
142
Error 38 Movement of X Motor Failed
143
Error 39 Movement of y Motor Failed
144
Error 40 Movement of S (Secondary Collimator) Motor Failed
145
Error 41 Movement of T (Cephalostat Sensor) Motor Failed
146
Error 42 Ceph IO Board Is Not Functioning
147
Error 43 Serial IO Board Error
148
Error 44 Mirror Door Open
148
Error 45 no X-Rays Detected on Cephalostat Sensor
148
Error 46 Emergency Stop Button Is Pressed
149
Error 47 Button Stuck
150
Error 48 Internal Failure
150
Error 49 Reading Panoramic Sensor Data Failed
151
Error 50 Reading Cephalostat Sensor Data Failed
152
Error 51 Cephalostat Sensor Missing
153
Error 52 Movement of L-Motor Failed
154
Error 100 Internal Communication Bus Error
155
Error 101 Incorrect Internal Message Format
155
GUI Error 103 External GUI Not Connected
156
GUI Error 104 Failed to Validate Calibration Data
156
Warnings and Notifications
157
Hardware Trouble Shooting
164
Internal and External Lans
164
No Ethernet Connection between the Unit and the Workstation
164
Connection between the Workstation and X-Ray Unit Is Lost from Time to Time
165
No Connection to R3300, R3400 and GUI PC (Internal Bus Failure)
165
Power Distribution (Mains)
166
Nothing Happens When the X-Ray Unit Is Switched On158
166
No X-Rays
166
Power Distribution (Low Voltages)
167
Nothing Happens When the X-Ray Unit Is Switched On159
167
Y- or Rotator Not Working
168
N-, Collimator- or Sensor Swap Not Working161
169
CEPH Sensor or Secondary Collimator Not Working162
170
The Panorama Imaging Not Working162
170
The 3D Imaging Not Working162
170
The CEPH Imaging Not Working163
171
R3220, R3300 or R3400 Does Not Operate163
171
Imaging
171
Generally Poor Image Quality
172
Reduced Gray Scale164
172
Shadows on the Projection Image164
172
Panorama Imaging
172
PAN Sensor Is Not Recognized164
172
Image Is Messy
173
Image Is too Dark or Light165
173
CEPH Imaging
173
Image Is Messy165
173
Image Is too Dark or Light
173
Exposure Control
173
Exposure Does Not Start When the Exposure Switch Is Pressed165
173
Exposure Sequence Starts but no X-Rays Are Generated
175
X-Ray Generation
176
No X-Rays Generated
176
Images too Dark or too Light (Wrong Dose Generated)169
177
Motion Control
179
Z-Motion Control
180
Main Support Up/Down (Z) Movement Does Not Work172
180
Calibration Program Numbers
183
Imaging Program Numbers
186
8 Maintenance Procedure
189
Advertisement
KaVo ORTHOPANTOMOGRAPH OP 3D Pro Installation Manual (168 pages)
3D Dental X-Ray System
Brand:
KaVo
| Category:
Medical Equipment
| Size: 5 MB
Table of Contents
Table of Contents
5
1 Introduction
9
ORTHOPANTOMOGRAPH™ OP 3D Pro
9
Intended Use
10
Associated Documentation
10
References
10
Abbreviations Used in this Manual
11
Warnings and Precautions
12
Warnings for Cross Infection
12
Warnings to be Observed During Installation and Service
12
Cautions for Electrostatic Discharge
14
General Warnings
14
Disclaimer
17
Disposal
17
2 Unit Description
19
Main Parts and Controls
19
Patient Positioning Lights
21
Patient Positioning Panel
25
Cephalometric Unit Positioning Panel
25
Main Control Panel
25
Unit Identification Labels
26
Unit Movements
27
Emergency Stop Switch
28
3 Pre-Installation Requirements
31
The Unit
31
Space Requirements
33
Fixing Hardware and Installation and Setup Tools
34
4 PC Requirements
35
Minimum PC Requirements
35
The Dental Imaging Software
37
5 Installing the Unit
39
Content of Delivery
39
The Column
39
The Carriage
45
Check Leveling
50
Installing Additional Set Screws and Connecting Cables
51
Attaching the Touch Screen Display to the Column (New Model)
53
Exposure Button
55
External Warning Light (Optional)
56
Installing the Cephalometric Unit
57
Enabling Carpus Imaging
68
6 Panoramic and 3D Calibrations and Adjustments
69
Introduction
69
When to Calibrate the Unit
70
Reset Maintenance Counter
71
Preparing for Calibration
71
The Calibration Sequence
74
Calibration of the Preheat of the Tube
74
Calibration of the Tube Current
74
Collimator Calibration
75
Beam Size Verification (Optional)
77
Panoramic Collimator Calibration
78
Panoramic Geometry Calibration
82
Geometry Calibration
83
SFOV (Small Panel) 3D Lasers Alignment
84
MFOV (Medium Panel) 3D Lasers Alignment
86
Panoramic Laser Alignment
90
Pixel Calibration
92
Panoramic Pixel Calibration
92
Quality Check
93
Panoramic Quality Check (Optional)
98
7 Cephalometric Calibration and Alignment
101
Preparations
101
Cephalometric Calibration Sequence
101
Balancing the Cephalostat
102
Primary Collimator Calibration
102
Rotation Angle Calibration
103
Mechanical Adjustment Program
105
Secondary Collimator Horizontal Adjustment
116
Cephalostat Laser Alignment
118
Cephalostat Pixel Calibration
119
Cephalostat Quality Check (Optional)
119
Ear Holder Alignment
121
Horizontal Adjustment
123
Vertical Adjustment
124
8 Special Procedures
125
General
125
Cephalometric Upgrade Kit
125
Changing the Cephalostat Arm Side
125
Changing the Cephalostat Arm Side in Service Mode
134
Adjusting and Calibrating the Cephalostat
135
Connecting the Unit to the Mains
136
Preparing the PC
139
Configuring the Communication Link to the PC
139
Firmware Update
141
Preparing for Update
141
Software Update
142
Automatic Update
142
Manual Update
142
Volatile Installation
146
Installation Procedure
147
Special Cases
150
Programming a R3220 Main CPU Board Having Wrong Unit Type Configured
150
Programming a Non-Responsive Cephalostat CPU
151
Troubleshooting
155
Problem: no Connection to the X-Ray Unit / R3220 Circuit Board
155
Problem: Automatic Software Update Fails
156
Problem: Manual Update Fails
156
Problem: S2Terminal Is Unable to Find Binary Files
156
Configurable Panoramic Mas Limit
157
9 OP 3D Pro Pre-Sales Check List
159
Physical Environment Requirements
159
Radiation Shielding Requirements
159
Mechanical Specifications
160
Electrical Specifications
160
Networking Specifications
161
Computer Specifications
162
Backup Specifications
162
DICOM Services SCP
162
Software Configuration
163
Other Information
164
Notes / Comments
165
Dimensions
166
Dimensions with Cephalostat
167
KaVo ORTHOPANTOMOGRAPH OP 3D Pro User Manual (117 pages)
ORTHOPANTOMOGRAPH
Brand:
KaVo
| Category:
Dental equipment
| Size: 7 MB
Table of Contents
Table of Contents
3
1 Disclaimer
6
2 Introduction
7
ORTHOPANTOMOGRAPH ™ OP 3D Pro
7
Intended Use
8
Indications for Use (USA Only)
8
Intended User Profile
8
Associated Documentation
8
References
8
Abbreviations Used in this Manual
8
Signal Words
9
Disposal
9
Warnings and Precautions
9
Warnings to be Observed During Use
9
Warnings for Cross Infection
10
General Warnings
11
3 Unit Description
13
Main Parts and Controls
13
Patient Positioning Lights
14
Patient Positioning Panel
16
Cephalometric Unit Patient Positioning Panel (Optional)
17
Accessories
18
Other Detachable Parts
19
Emergency Stop Switch
20
Patient Contacting Parts
20
4 Imaging Programs
21
Panoramic Programs
21
Sectional Imaging
27
Panoramic Automatic Dose Control (ADC)
28
Orthofocus
29
Multilayer Selection
29
User Configurable Panoramic Ma Level
30
User Configurable Default Program
30
Cephalometric Programs
30
Programs, Small Panel
34
Programs, Medium Panel
35
Selecting Resolution and FOV
38
Automatic Dose Control (ADC)
38
MAR, Metal Artifact Reduction
39
Exposure Settings for 3D Imaging
40
5 Touch Screen Display
42
Main Control Panel
42
Modality Section
42
Exposure Indicators and Settings
43
Status Section
43
Other Sections
44
6 Using the Unit
45
Attaching and Removing the Sensor
45
Preparing the System
46
Panoramic Exposures
47
Positioning Devices
47
General Instructions
48
Panoramic Patient Positioning
49
TMJ Patient Positioning
53
Maxillary Sinus Patient Positioning
55
Taking a Panoramic Exposure
56
Cephalometric Exposures
57
General Instructions
58
Patient Positioning
59
Taking a Cephalometric Exposure
63
Exposures
64
General Instructions
64
Patient Positioning
65
Scout Image
69
Image
71
Warnings and Error Messages
73
Acknowledging Errors
73
Image Transfer Errors
73
7 Troubleshooting
74
Patient Positioning
75
Image Appearance
77
Artefacts
78
Unit Operation
79
8 Maintenance
80
Maintenance Procedure
80
Annual Maintenance
80
Calibration Intervals
80
Changing the Fuses
80
Cleaning and Decontaminating the Unit
80
9 Calibration and Adjustment
83
Introduction
83
Preparing for Calibration
83
Panoramic Calibration
83
Panoramic Geometry Calibration
84
Panoramic Pixel Calibration
84
Panoramic Quality Check (Optional)
85
Calibration
86
Geometry Calibration
86
Pixel Calibration
87
Quality Check Program
88
Cephalometric Calibration
89
Ceph Pixel Calibration
89
Ceph Quality Check Program (Optional)
90
10 Technical Data
92
Technical Specifications
92
Unit Dimensions
104
Symbols that May Appear on the Device or Its Parts
107
Labels on the Unit
109
Electromagnetic Compatibility (EMC) Tables
109
X-Ray Tube Assemblies
113
11 PC Requirements
115
Minimum PC Requirements
115
The Dental Imaging Software
116
Advertisement
Advertisement
Related Products
KaVo ORTHOPANTOMOGRAPH OP 3D
KaVo ORTHOPANTOMOGAPH OP 2D
KaVo OP 3D Vision
KaVo OP 3D Pro
KaVo OP300-1
KaVo 0.524.5620
KaVo 0.571.5020
KaVo 1.002.2179
KaVo 1.003.7701
KaVo 1.003.7702
KaVo Categories
Dental equipment
Medical Equipment
Laboratory Equipment
Media Converter
Accessories
More KaVo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL