Appendix: Technical data
Ambient temperature
Maximum humidity
Installation surface / water spray The device must be placed and leveled on
Installation clearances
Installation dimensions of the
water filter
86
+5 °C to +35 °C
(empty the water system in case of frost).
80 % relative humidity without condensation.
Do not use device outdoors.
a horizontal, sturdy, water-resistant, and
heatproof base.
The device must not be cleaned using a water
jet. The device must be installed where it is
protected against water spray. The device must
not be located on a surface that is sprayed or
cleaned with a water hose, steam jets, steam
cleaner, or similar devices.
For operating, service and safety reasons the
machine should be installed with a clearance of
not less than 50 mm at the back and sides from
the building or non-WMF components.
A minimum working space of 800 mm in front
the coffee machine and overhead clearance of
at least 200 mm above the product hoppers are
recommended. A clear height of 1,100 mm from
the top of the installation surface should be
ensured. The height of the installation surface
above the floor is at least 850 mm. If the coffee
machine connections are to be run downwards
through the counter, please make space for the
lines, which can reduce the usable space below
the coffee machine.
See the User Manual for the water filter.
User Manual WMF 5000 S