5.7.3
Peak value function
This function displays the highest load value (peak value) of a weighing.
Measuring frequency: 200ms
Attention:
Never exceed the maximum permitted load of the peak value on the
balance (!!Danger of breaking!!).
• Switch on balance using the ON/OFF/TARE–button
• Press the HOLD-button and keep it pressed until „H x" in the display appears
• Press the ON/OFF/TARE until „H6" in the display appears
• Save the setting by shortly pressing the HOLD-button
• Suspend a load
• The peak value function is displayed by a [] upside left
A negative value [-] is displayed as soon as the balance is relieved

6. Menu

 When the balance is switched off, press the HOLD-key and keep it pressed
 Do not release the HOLD-key. Press also the ON/OFF/TARE-key and keep it
pressed
 Keep the ON/OFF/TARE-key pressed, however release the HOLD-key
 Press HOLD-key anew
 Keep both keys pressed until in the display "tr" appears
 Release both keys. The balance is situated in the menu.
 Using the ON/OFF/TARE button you can select between the following functions:
 tr (Zero tracking): ON/OFF
 AF (Auto off): ON/OFF
 rST (reset to factory settings): YES/NO
 Press the HOLD button to confirm the selected function
 In the display appears the current setting „ON" or „OFF" resp. „YES" or „NO". You
can select between „ON" or „OFF" and/or „YES" or „NO" with the
ON/OFF/TARE-button. Confirm your selection with the HOLD-key. After a short
period the balance returns automatically to weighing mode.