Download Print this page

Converting The Main Gas Control Regulator; Checking The Gas Pressure; Adjusting The Pilot Burner - Montigo H34D Conversion Instructions

Advertisement

Gas Conversion Kit
9.
Install the new orifice from the conversion kit to convert to the
pilot to the new gas. Tighten the orifice securely with an allen
key. Re-attach the pilot hood, making sure the notch in the hood
lines up with the tab on the pilot assembly.
Figure 4. The Pilot Assembly, with cap off. The pilot hood will snap
off; the orifice must be removed with an allen key.
Main Gas Control Regulator:
10. The SIT Hi/Lo gas control valve supplied with this appliance has
a removable regulator. To replace it, remove the three screws
as shown in Figure 6, and install the new regulator supplied with
this kit.
Figure 6. Replacing the regulator on the Sit Nova 820 gas control valve.
11. The label (part no. LB0205/LB0206) indicating that the fireplace
has been converted for use with a different gas must be placed
on the fireplace rating plate over top of the existing fuel type
marking.
The label (part no. LB0207/LB0206) indicating who converted
the appliance must be filled out and placed on the base pan,
directly under the gas valve.
Also place the label indicating that the control valve has been
Page 
Gas Conversion Instructions
remove screws to
replace regulator

Checking the Gas Pressure

To check the Inlet and Manifold gas pressures, a Water Column Pres-
sure Gauge with 5/16" dia. tubing can be used. To test the Manifold
Pressure, loosen the screw shown in Figure 7. Attach the gauge to
the Manifold Pressure Test Connection and open the gas shut-off
valve. The tubing must be tight in the connection to prevent gas leaks.
Measure the Manifold Pressure and compare the value against the
chart below.
Pilot Adjustment Screw
Inlet
Pressure
Manifold Pressure
Test Connection
Figure 7. Sit Nova 820 series gas valve.
Manifold Pressure (min.)
Inlet Pressure (min.- max.)
" W.C. = inches water column
Turn off the fireplace and close the shutoff valve. Remove the test
gauge. Re-tighten the test connection screw to prevent gas leak-
age.
Repeat the procedure for the Inlet Pressure.
If the pressure readings are not within the limits set out, contact the
factory. If the pressure readings are correct, ensure that both test con-
nection screws are tightened securely, to prevent a gas leak.
Pilot Burner Adjustment
1. Locate the Pilot Adjustment Screw on the gas control valve. (See
figure 7)
2. Adjust pilot screw to provide properly sized flame as shown in fig-
ure 8). To increasethe flame, turn the screw counterclockwise. To
decrease the flame, turn it clockwise. The flame should impinge
on the thermocouple and thermopile.
3. After installing or servicing, leak test using a soap solution with
main burner turned on. Coat pipe and tubing joints, gasket etc.
with soap solution. Bubbles indicate leaks. Tighten any areas
where the bubbles appear until the bubbling stops completely.
Figure 8. Pilot Burner
Power
Generator
Wall Switch
Natural Gas
Liquid Propane
3.5" W.C.
10" W.C.
5.5" - 14" W.C.
11" - 14" W.C.
P/N XG0675

Advertisement