Section 3: Wiring; Honeywell Gas Control And Pilot - Montigo H38SVO-ST Installation And Maintenance Manual

Outdoor ventless see through residential gas fireplace
Table of Contents

Advertisement

H*38VO-ST Outdoor Gas Fireplace

Section 3: Wiring

Installing The Remote Switch (H(L)VO-ST)
The H*38VO-ST* gas valve, located behind the lower trim, may be
connected to a wall switch. The valve generates its own power on a
millivolt circuit. Use only low voltage wire, and DO NOT connect
any external power to it.
Refer to Figure 4 for wiring requirements.
Note: The switch location must not exceed 30' from the fireplace.
Page 8
Installation
Honeywell (Q3450)
Pilot Assembly
Gas Control
Connector
Figure 7. Wiring for the H(L)38VO-ST (N,L)E Honeywell gas control and pilot.
Pilot Adjsutment Screw
Inlet Pressure
Figure 8. Standing Pilot Diagram (H(L)38VO-ST)
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Wall
Water tight
Switch
Electrical box
Manifold Pressure
Test Connection
Use Montigo Part No. #RPOVO Water-tight electrical box, or
equivalent equipment. Ensure the box is installed in a dry location
and avoid any moisture.
If you install 115V Wire, ensure you use Ground fault breakers.
Also avoid any moisture near or around the 115V Circuit.
Source 110V
Distribution
Panel
White
Black
Power
Generator
Wall Switch
WARNING!
XG0817 - 140707.2