Andon KD-7965 Operation Manual

Fully automatic wrist cuff blood pressure monitor (electronic sphygmomanometer)

Advertisement

Quick Links

DN:KD-7965-SMSY01 V3.0
Fully Automatic Wrist Cuff Blood Pressure Monitor
IMPORTANT INFORMATION ..................................................................................................................................... 2
CONTENTS AND DISPLAY INDICATORS ............................................................................................................... 2
INTENDED USE ........................................................................................................................................................... 3
CONTRAINDICATION .................................................................................................................................................. 3
PRODUCT DESCRIPTION ......................................................................................................................................... 3
SPECIFICATIONS ........................................................................................................................................................ 3
NOTICE .......................................................................................................................................................................... 4
SETUP AND OPERATING PROCEDURES ............................................................................................................. 5
1. BATTERY LOADING ........................................................................................................................................ 5
2. TOUCH SCREEN SWITCH ............................................................................................................................... 6
3. CLOCK AND DATE ADJUSTMENT ................................................................................................................ 6
4. VOICE SETTING ............................................................................................................................................... 6
5. CONNECTING THE CUFF TO THE MONITOR ............................................................................................. 7
6. APPLYING THE CUFF ...................................................................................................................................... 7
7. BODY POSTURE DURING MEASUREMENT ................................................................................................ 7
8. TAKING YOUR BLOOD PRESSURE READING ............................................................................................ 8
9. DISPLAYING STORED RESULTS ................................................................................................................... 8
10. DELETING MEASUREMENTS FROM THE MEMORY .............................................................................. 9
11. ASSESSING HIGH BLOOD PRESSURE FOR ADULTS ............................................................................... 9
12. TECHNICAL ALARM DESCRIPTION ........................................................................................................... 9
13.TROUBLESHOOTING (1) .............................................................................................................................. 10
14. TROUBLESHOOTING (2) ............................................................................................................................. 10
MAINTENANCE .......................................................................................................................................................... 11
EXPLANATION OF SYMBOLS ON UNIT ............................................................................................................... 11
WARRANTY INFORMATION .................................................................................................................................... 12
SERVICE CENTER .................................................................................................................................................... 12
ELECTROMAGNETIC COMPATIBILITY INFORMATION .................................................................................... 12
MODEL KD-7965
(ELECTRONIC SPHYGMOMANOMETER)
INDEX
1/15
Operation Guide
Template version:1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KD-7965 and is the answer not in the manual?

Questions and answers

Summary of Contents for Andon KD-7965

  • Page 1: Table Of Contents

    DN:KD-7965-SMSY01 V3.0 Operation Guide MODEL KD-7965 Fully Automatic Wrist Cuff Blood Pressure Monitor (ELECTRONIC SPHYGMOMANOMETER) OPERATION GUIDE INDEX IMPORTANT INFORMATION ............................. 2 CONTENTS AND DISPLAY INDICATORS ....................... 2 INTENDED USE ................................3 CONTRAINDICATION ..............................3 PRODUCT DESCRIPTION ............................3 SPECIFICATIONS ................................ 3 NOTICE ..................................
  • Page 2: Operation Guide

    DN:KD-7965-SMSY01 V3.0 Operation Guide IMPORTANT INFORMATION NORMAL BLOOD PRESSURE FLUCTUATION All physical activity, excitement, stress, eating, drinking, smoking, body posture and many other activities or factors (including taking a blood pressure measurement) will influence blood pressure value. Because of this, it is mostly unusual to obtain identical multiple blood pressure readings.
  • Page 3: Intended Use

    Supplementary requirements for electro-mechanical blood pressure measuring systems), ANSI/AAMI SP-10:2002+A1:2003+A2:2006. SPECIFICATIONS 1. Product name: Blood Pressure Monitor 2. Model: KD-7965 3. Classification: Internally powered, Type BF applied part,IPX0,No AP or APG, Continuous operation 4. Machine size: 88mm x 66mm x 28.7mm 5. Cuff circumference: 14-19.5cm/5.5-7.7inches 6.
  • Page 4: Notice

    DN:KD-7965-SMSY01 V3.0 Operation Guide Systolic: 60-260mmHg Diastolic: 40-199mmHg Pulse rate: 40-180 beats/minute 11. Accuracy: Pressure: ±3mmHg Pulse rate: ±5% 12. Environmental temperature for operation: 5℃~40℃(41℉~104℉) 13. Environmental humidity for operation: ≤90%RH 14. Environmental temperature for storage and transport: -20℃~55℃(-4℉~131℉) 15. Environmental humidity for storage and transport: ≤90%RH 16.
  • Page 5: Setup And Operating Procedures

    DN:KD-7965-SMSY01 V3.0 Operation Guide 12. If Irregular Heartbeat (IHB) brought by common arrhythmias is detected in the procedure of blood pressure measurement, a signal of will be displayed. Under this condition, the Electronic Sphygmomanometer can keep function, but the results may not be accurate, it’s suggested that you consult with your physician for accurate assessment.
  • Page 6: Touch Screen Switch

    DN:KD-7965-SMSY01 V3.0 Operation Guide The monitor, the batteries and the cuff, must be disposed of according to local regulations at the end of their usage. 2. TOUCH SCREEN SWITCH Your monitor has a touch screen as equipment. Be careful not to touch the screen by mistake. Keep the touch switch in ―OFF‖...
  • Page 7: Connecting The Cuff To The Monitor

    DN:KD-7965-SMSY01 V3.0 Operation Guide Picture 4 Picture 4-1 Picture 4- 2 Picture 4-3 c. Voice volume setting: Once you have selected a language, a column of bar will appear on the LCD. Keep on pressing the button ―MEM‖ again, you can adjust the volume.
  • Page 8: Taking Your Blood Pressure Reading

    DN:KD-7965-SMSY01 V3.0 Operation Guide 8. TAKING YOUR BLOOD PRESSURE READING a. Ensure the touch screen switch in ON position. b. After applying the cuff and your body is in a comfortable position, press the ―START‖ button, all display characters are shown for self-test.
  • Page 9: Deleting Measurements From The Memory

    DN:KD-7965-SMSY01 V3.0 Operation Guide 10. DELETING MEASUREMENTS FROM THE MEMORY When any result is displaying, keep on pressing button ―MEM‖ for three seconds, all results in the memory bank will be deleted after three ―beep‖. Press the button ―MEM‖ or ―START‖, See picture 10 &...
  • Page 10: Troubleshooting (1)

    DN:KD-7965-SMSY01 V3.0 Operation Guide 13.TROUBLESHOOTING (1) PROBLEM POSSIBLE CAUSE SOLUTION LCD Display shows Low Battery Change the batteries battery symbol Re-test taking care to not Arm or blood pressure monitor move your arm or the blood was moved during testing...
  • Page 11: Maintenance

    DN:KD-7965-SMSY01 V3.0 Operation Guide MAINTENANCE Do not drop this monitor or subject it to strong impact. Avoid high temperature and solarization. Do not immerse the monitor in water as this will result in damage to the monitor. If this monitor is stored near freezing, allow it to acclimate to room temperature before use.
  • Page 12: Warranty Information

    For all ME EQUIPMENT and ME SYSTEMS Guidance and manufacture’s declaration - electromagnetic emissions The KD-7965 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-7965 should assure that it is used in such an environment. Emissions test...
  • Page 13 Guidance and manufacturer’s declaration - electromagnetic immunity The KD-7965 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-7965 should assure that it is used in such an environment. Electromagnetic IMMUNITY test...
  • Page 14 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the KD-7965 is used exceeds the applicable RF compliance level above, the KD-7965 should be observed to verify normal operation.
  • Page 15 Recommended separation distances between portable and mobile RF communications equipment and the KD-7965 The KD-7965 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the KD-7965 can help prevent...

Table of Contents