Andon KD-5985 Operation Manual

Fully automatic arm cuff blood pressure monitor

Advertisement

Quick Links

DN:KD-5985-SMSY01 V3.0
Fully Automatic Arm Cuff Blood Pressure Monitor
__________________________________________________________________________
IMPORTANT INFORMATION ......................................................................... 2
PARTS AND DISPLAY INDICATORS ............................................................ 2
INTENDED USE .............................................................................................. 3
CONTRAINDICATION ..................................................................................... 3
PRODUCT DESCRIPTION .............................................................................. 3
SPECIFICATIONS ........................................................................................... 4
NOTICE ........................................................................................................... 5
SETUP AND OPERATING PROCEDURES .................................................... 6
1.
BATTERY LOADING AND AC ADAPTER LOADING ............................................. 6
2.
SETTING .................................................................................................................... 7
2.1 ALARM SETTING ....................................................................................................................... 7
2.2 VOICE SETTING ......................................................................................................................... 8
2.3 CLOCK AND DATE ADJUSTMENT ......................................................................................... 8
2.4 RCC(Radio Controlled Clock) ....................................................................................................... 9
3.
CONNECTING THE CUFF TO THE MONITOR ........................................................ 9
4.
APPLYING THE CUFF ............................................................................................ 10
5.
BODY POSTURE DURING MEASUREMENT ........................................................ 10
6.
GROUP SELCET ..................................................................................................... 10
7.
TAKING YOUR BLOOD PRESSURE READING ................................................... 11
8.
DISPLAYING STORED RESULTS ......................................................................... 11
9.
DELETING MEASUREMENTS FROM THE MEMORY .......................................... 12
10.
RADIO ...................................................................................................................... 12
11.
OTHERS ................................................................................................................... 13
12.
ASSESSING HIGH BLOOD PRESSURE FOR ADULTS ....................................... 13
13.
TECHNICAL ALARM DESCRIPTION ..................................................................... 15
14.
TROUBLESHOOTING (1) ....................................................................................... 15
15.
TROUBLESHOOTING (2) ....................................................................................... 15
MAINTENANCE ............................................................................................ 17
EXPLANATION OF SYMBOLS ON UNIT ..................................................... 17
WARRANTY INFORMATION ........................................................................ 18
SERVICE CENTER ....................................................................................... 18
ELECTROMAGNETIC COMPATIBILITY INFORMATION ............................ 18
MODEL KD-5985
(ELECTRONIC SPHYGMOMANOMETER)
OPERATION GUIDE
INDEX
1/22
Operation Guide
Template version:1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KD-5985 and is the answer not in the manual?

Questions and answers

Summary of Contents for Andon KD-5985

  • Page 1: Table Of Contents

    DN:KD-5985-SMSY01 V3.0 Operation Guide MODEL KD-5985 Fully Automatic Arm Cuff Blood Pressure Monitor (ELECTRONIC SPHYGMOMANOMETER) OPERATION GUIDE __________________________________________________________________________ INDEX IMPORTANT INFORMATION ................. 2 PARTS AND DISPLAY INDICATORS ............2 INTENDED USE ....................3 CONTRAINDICATION ..................3 PRODUCT DESCRIPTION ................3 SPECIFICATIONS ...................
  • Page 2: Important Information

    DN:KD-5985-SMSY01 V3.0 Operation Guide IMPORTANT INFORMATION NORMAL BLOOD PRESSURE FLUCTUATION All physical activity, excitement, stress, eating, drinking, smoking and many other activities or factors (including taking a blood pressure measurement) will influence blood pressure value. Because of this, it is mostly unusual to obtain identical multiple blood pressure readings.
  • Page 3: Intended Use

    DN:KD-5985-SMSY01 V3.0 Operation Guide INTENDED USE Fully Automatic Electronic Sphygmomanometer is for use by medical professionals or at home and is a non-invasive blood pressure measurement system intended to measure the diastolic and systolic blood pressures and pulse rate of an adult individual by using a non-invasive technique in which an inflatable cuff is wrapped around the upper arm.
  • Page 4: Specifications

    Clock Mode. With a radio chip, the monitor can be used as a radio. SPECIFICATIONS 1. Product name: Blood Pressure Monitor 2. Model: KD-5985 3. Classification: class II, Internally powered, Type BF applied part,IPX0,No AP or APG, Continuous operation 4. Machine size: 203mm×180mm×81mm(approximate:8’’ ×7 3/32’’ ×3 3/16’’) 5.
  • Page 5: Notice

    DN:KD-5985-SMSY01 V3.0 Operation Guide Note: These specifications are subject to change without notice. NOTICE 1. Read all of the information in the operation guide and any other literature in the box before operating the unit. 2. Stay quiet, calm and rest for 5 minutes before blood pressure measurement.
  • Page 6: Setup And Operating Procedures

    DN:KD-5985-SMSY01 V3.0 Operation Guide The monitor might not meet its performance specifications or cause safety hazard if stored or used outside the specified temperature and humidity ranges in specifications. Please do not share the cuff with other infective person to avoid cross-infection.
  • Page 7: Setting

    DN:KD-5985-SMSY01 V3.0 Operation Guide When LCD shows battery symbol , replace all batteries with new ones. Rechargeable batteries are not suitable for this monitor. Remove the batteries if the monitor will not be used for a month or more to avoid relevant damage of battery leakage Avoid the battery fluid to get in your eyes.
  • Page 8: Voice Setting

    DN:KD-5985-SMSY01 V3.0 Operation Guide A+", the number will increase fast. Keep on pressing the button ―B-‖, the number will reduce fast. b. You can turn off the monitor by pressing ―SET‖ button when enable or disable option is blinking and it be set disable , then the setting is confirmed.
  • Page 9: Rcc(Radio Controlled Clock)

    DN:KD-5985-SMSY01 V3.0 Operation Guide date unchanged. d. The monitor will turn off if you press the button ―START‖ with the time and date unchanged. e. Once you change the batteries, you should readjust the time and date. 2.4 RCC(Radio Controlled Clock) Initial receiving: Once you install the battery, the machine enters the RCC receiving mode.
  • Page 10: Applying The Cuff

    DN:KD-5985-SMSY01 V3.0 Operation Guide Avoid compression or restriction of the connection tubing during measurement,which may cause inflation error, or harmful injury due to continuous cuff pressure. APPLYING THE CUFF a. Pulling the cuff end through the medal loop (the cuff is packaged like this already), turn it outward (away from your body) and tighten it and close the Velcro fastener.
  • Page 11: Taking Your Blood Pressure Reading

    DN:KD-5985-SMSY01 V3.0 Operation Guide When the monitor is working in Clock mode, you can press the A+ or B- button to change the memory bank. The monitor has there bank: user 1 user 2 and guest. There are especial symbol stand for user 1 and use 2. If you select guest bank the especial symbols will disappear and the measurement result doesn’t be stored.
  • Page 12: Deleting Measurements From The Memory

    DN:KD-5985-SMSY01 V3.0 Operation Guide a. Press ―MEM‖ button in Clock Mode to display the stored results. The amount of results in current bank will be displayed. About 1 second later, the LCD will display the average value of all results in this bank. If the voice function is on, the monitor will announce the average value.
  • Page 13: Others

    DN:KD-5985-SMSY01 V3.0 Operation Guide The radio support worldwide frequency band is 87 -108 MHz. b. Pressure ―A+‖ button, the monitor will seek up for another broadcasting station base on the frequency of current broadcasting station. Pressure ―B-+‖ button, the monitor will seek down for another broadcasting station.
  • Page 14 DN:KD-5985-SMSY01 V3.0 Operation Guide It is not intended to provide a basis of any type of rush toward emergency conditions/diagnosis based on the color scheme and that the color scheme is meant only to discriminate between the different levels of blood pressure.
  • Page 15: Technical Alarm Description

    DN:KD-5985-SMSY01 V3.0 Operation Guide 13. TECHNICAL ALARM DESCRIPTION The monitor will show 'SYS HI','SYS Lo' ,'DIA HI' or 'DIA Lo' as technical alarm on LCD with no delay if the determined blood pressure (systolic or diastolic) is outside the rated range specified in part SPECIFICACIONS.
  • Page 16 DN:KD-5985-SMSY01 V3.0 Operation Guide cuff is too loose during inflation LCD shows ―Er 5‖ Cuff pressure above 300mmHg LCD shows ―Er 6‖ Measure again after five More than 160 seconds with cuff minutes. If the monitor is pressure above 15 mmHg LCD shows ―Er 7‖...
  • Page 17: Maintenance

    DN:KD-5985-SMSY01 V3.0 Operation Guide MAINTENANCE Do not drop this monitor or subject it to strong impact. Avoid high temperature and solarization. Do not immerse the monitor in water as this will result in damage to the monitor. If this monitor is stored near freezing, allow it to acclimate to room temperature before use.
  • Page 18: Warranty Information

    For all ME EQUIPMENT and ME SYSTEMS Guidance and manufacture’s declaration - electromagnetic emissions The KD-5985 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-5985 should assure that it is used in such an environment. Emissions test...
  • Page 19 Guidance and manufacturer’s declaration - electromagnetic immunity The KD-5985 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-5985 should assure that it is used in such an environment. Electromagnetic IMMUNITY test...
  • Page 20 Guidance and manufacturer’s declaration - electromagnetic immunity The KD-5985 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-5985 should assure that it is used in such an environment. IMMUNITY IEC 60601test...
  • Page 21 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the KD-5985 is used exceeds the applicable RF compliance level above, the KD-5985 should be observed to verify normal operation.
  • Page 22 DN:KD-5985-SMSY01 V3.0 Operation Guide 0,38 0,38 0,73 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be determined using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.

Table of Contents