Andon KD-322 Operation Manual

Semi automatic arm cuff blood pressure monitor

Advertisement

DN:KD-322-SMSY01 V4.0
Semi Automatic Arm Cuff Blood Pressure Monitor
__________________________________________________________________________
IMPORTANT INFORMATION ......................................................................... 2
CONTENTS AND DISPLAY INDICATORS ..................................................... 2
INTENDED USE .............................................................................................. 3
CONTRAINDICATION ..................................................................................... 3
PRODUCT DESCRIPTION .............................................................................. 3
SPECIFICATIONS ........................................................................................... 4
NOTICE ........................................................................................................... 4
SETUP AND OPERATING PROCEDURES .................................................... 6
1.
BATTERY LOADING ............................................................................... 6
2.
CONNECTING THE CUFF TO THE MONITOR ....................................... 6
3.
APPLYING THE CUFF ............................................................................. 6
4.
BODY POSTURE DURING MEASUREMENT ......................................... 7
5.
TAKING YOUR BLOOD PRESSURE READING ..................................... 7
6.
ASSESSING HIGH BLOOD PRESSURE FOR ADULTS ........................ 8
7.
TROUBLESHOOTING (1) ........................................................................ 9
8.
TROUBLESHOOTING (2) ........................................................................ 9
MAINTENANCE ............................................................................................ 10
EXPLANATION OF SYMBOLS ON UNIT ..................................................... 10
WARRANTY INFORMATION ........................................................................ 11
SERVICE CENTER ....................................................................................... 11
ELECTROMAGNETIC COMPATIBILITY INFORMATION ............................ 11
MODEL KD-322
(ELECTRONIC SPHYGMOMANOMETER)
OPERATION GUIDE
INDEX
1/14
Operation Guide
Template version:1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KD-322 and is the answer not in the manual?

Questions and answers

Summary of Contents for Andon KD-322

  • Page 1: Table Of Contents

    DN:KD-322-SMSY01 V4.0 Operation Guide MODEL KD-322 Semi Automatic Arm Cuff Blood Pressure Monitor (ELECTRONIC SPHYGMOMANOMETER) OPERATION GUIDE __________________________________________________________________________ INDEX IMPORTANT INFORMATION ................. 2 CONTENTS AND DISPLAY INDICATORS ............. 2 INTENDED USE ....................3 CONTRAINDICATION ..................3 PRODUCT DESCRIPTION ................3 SPECIFICATIONS ...................
  • Page 2: Important Information

    DN:KD-322-SMSY01 V4.0 Operation Guide IMPORTANT INFORMATION NORMAL BLOOD PRESSURE FLUCTUATION All physical activity, excitement, stress, eating, drinking, smoking, body posture and many other activities or factors (including taking a blood pressure measurement) will influence blood pressure value. Because of this, it is mostly unusual to obtain identical multiple blood pressure readings.
  • Page 3: Intended Use

    DN:KD-322-SMSY01 V4.0 Operation Guide INTENDED USE Semi-Automatic Blood Pressure Monitor is for use by medical professionals or at home and is a non-invasive blood pressure measurement system intended to measure the diastolic and systolic blood pressures and pulse rate of an adult individual by using a non-invasive technique in which an inflatable cuff is wrapped around the upper arm.
  • Page 4: Specifications

    DN:KD-322-SMSY01 V4.0 Operation Guide SPECIFICATIONS 1. Product name: Blood Pressure Monitor 2. Model: KD-322 3. Classification: Internally powered, Type BF applied part,IPX0,No AP or APG,Continuous operation 4. Machine size: approx. 144mm×102mm×46mm (5 21/32” x 4 1/32” x 1 13/16”) 5. Cuff circumference: 22cm-30cm(8 21/32” -11 13/16”), 30cm-42cm(11 13/16” -16 17/32”) (Optional), 42cm-48cm(16 17/32”...
  • Page 5 DN:KD-322-SMSY01 V4.0 Operation Guide 7. Consult your physician if you have any doubt about below cases: 1) The application of the cuff over a wound or inflammation diseases; 2) The application of the cuff on any limb where intravascular access or therapy, or an arterio-venous (A-V) shunt, is present;...
  • Page 6: Setup And Operating Procedures

    DN:KD-322-SMSY01 V4.0 Operation Guide SETUP AND OPERATING PROCEDURES 1. BATTERY LOADING a. Open battery cover at the back of the monitor. b. Load four “AA” size batteries. Please pay attention to polarity. c. Close the battery cover. When LCD shows battery symbol , replace all batteries with new ones.
  • Page 7: Body Posture During Measurement

    DN:KD-322-SMSY01 V4.0 Operation Guide Please refer to the cuff circumference range in “SPECIFICATIONS” to make sure that the appropriate cuff is used. Measuring on same arm each time. Do not move your arm, body, or the monitor and do not move the rubber tube during measurement.
  • Page 8: Assessing High Blood Pressure For Adults

    DN:KD-322-SMSY01 V4.0 Operation Guide e. After reading the result, press the exhaust valve which is located in the front of the bulb to release the air. When all the air is pushed out of the cuff, BPM will blink , then you can start measuring again.
  • Page 9: Troubleshooting (1)

    DN:KD-322-SMSY01 V4.0 Operation Guide 7. TROUBLESHOOTING (1) PROBLEM POSSIBLE CAUSE SOLUTION LCD Display shows Low Battery Change all the batteries battery symbol Arm or blood pressure Re-test taking care to not monitor was moved move your arm or the during testing...
  • Page 10: Maintenance

    DN:KD-322-SMSY01 V4.0 Operation Guide MAINTENANCE Do not drop this monitor or subject it to strong impact. Avoid high temperature and solarization. Do not immerse the monitor in water as this will result in damage to the monitor. If this monitor is stored near freezing, allow it to acclimate to room temperature before use.
  • Page 11: Warranty Information

    For all ME EQUIPMENT and ME SYSTEMS Guidance and manufacture’s declaration - electromagnetic emissions The KD-322 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-322 should assure that it is used in such an environment. Emissions test...
  • Page 12 DN:KD-322-SMSY01 V4.0 Operation Guide The KD-322 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-322 should assure that it is used in such an environment. Electromagnetic IMMUNITY test IEC 60601test level...
  • Page 13 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the KD-322 is used exceeds the applicable RF compliance level above, the KD-322 should be observed to verify normal operation.
  • Page 14 DN:KD-322-SMSY01 V4.0 Operation Guide electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the KD-322 as recommended below, according to the maximum output power of the communications equipment. Rated maximum Separation distance according to frequency of transmitter...