Andon KD-7961N Operation Manual

Fully automatic wrist cuff blood pressure monitor

Advertisement

DN:KD-7961N-SMSY01 V3.0
Fully Automatic Wrist Cuff Blood Pressure Monitor
IMPORTANT INFORMATION ..................................................................................................................................... 2
CONTENTS AND DISPLAY INDICATORS ............................................................................................................... 2
INTENDED USE ........................................................................................................................................................... 3
CONTRAINDICATION .................................................................................................................................................. 3
PRODUCT DESCRIPTION ......................................................................................................................................... 3
SPECIFICATIONS ........................................................................................................................................................ 3
NOTICE .......................................................................................................................................................................... 4
SETUP AND OPERATING PROCEDURES ............................................................................................................. 5
1. BATTERY LOADING ........................................................................................................................................ 5
2. TOUCH BUTTON SWITCH .............................................................................................................................. 6
3. CLOCK AND DATE ADJUSTMENT ................................................................................................................ 6
4. VOICE SETTING ............................................................................................................................................... 6
5. CONNECTING THE CUFF TO THE MONITOR ............................................................................................. 7
6. APPLYING THE CUFF ...................................................................................................................................... 7
7. BODY POSTURE DURING MEASUREMENT ................................................................................................ 7
8. TAKING YOUR BLOOD PRESSURE READING ............................................................................................ 8
9. DISPLAYING STORED RESULTS ................................................................................................................... 8
10. DELETING MEASUREMENTS FROM THE MEMORY .............................................................................. 9
11. ASSESSING HIGH BLOOD PRESSURE FOR ADULTS ............................................................................... 9
12. TECHNICAL ALARM DESCRIPTION ......................................................................................................... 10
13.TROUBLESHOOTING (1) .............................................................................................................................. 10
14. TROUBLESHOOTING (2) ............................................................................................................................. 10
MAINTENANCE .......................................................................................................................................................... 11
EXPLANATION OF SYMBOLS ON UNIT ............................................................................................................... 11
WARRANTY INFORMATION .................................................................................................................................... 12
SERVICE CENTER .................................................................................................................................................... 12
ELECTROMAGNETIC COMPATIBILITY INFORMATION .................................................................................... 12
MODEL KD-7961N
(ELECTRONIC SPHYGMOMANOMETER)
INDEX
1/15
Operation Guide
Template version:1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KD-7961N and is the answer not in the manual?

Questions and answers

Summary of Contents for Andon KD-7961N

  • Page 1: Table Of Contents

    DN:KD-7961N-SMSY01 V3.0 Operation Guide MODEL KD-7961N Fully Automatic Wrist Cuff Blood Pressure Monitor (ELECTRONIC SPHYGMOMANOMETER) OPERATION GUIDE INDEX IMPORTANT INFORMATION ............................. 2 CONTENTS AND DISPLAY INDICATORS ....................... 2 INTENDED USE ................................3 CONTRAINDICATION ..............................3 PRODUCT DESCRIPTION ............................3 SPECIFICATIONS ................................ 3 NOTICE ..................................
  • Page 2: Operation Guide

    DN:KD-7961N-SMSY01 V3.0 Operation Guide IMPORTANT INFORMATION NORMAL BLOOD PRESSURE FLUCTUATION All physical activity, excitement, stress, eating, drinking, smoking, body posture and many other activities or factors (including taking a blood pressure measurement) will influence blood pressure value. Because of this, it is mostly unusual to obtain identical multiple blood pressure readings.
  • Page 3: Intended Use

    SPECIFICATIONS 1. Product name: Blood Pressure Monitor 2. Model: KD-7961N 3. Classification: Internally powered, Type BF applied part,IPX0,No AP or APG, Continuous operation 4. Machine size: 85mm x 69mm x 30mm ( 3 11/32″ x 2 23/32″ x 1 3/16″) 5.
  • Page 4: Notice

    DN:KD-7961N-SMSY01 V3.0 Operation Guide 8. Memory volume: 60 times with time and date stamp 9. Power source: 2 ×1.5V SIZE AAA batteries 10. Measurement range: Cuff pressure: 0-300mmHg Systolic: 60-260mmHg Diastolic: 40-199mmHg Pulse rate: 40-180 beats/minute 11. Accuracy: Pressure: ±3mmHg Pulse rate: ±5%...
  • Page 5: Setup And Operating Procedures

    DN:KD-7961N-SMSY01 V3.0 Operation Guide 10. Blood pressure measurements determined by this monitor are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard Institute, Electronic or automated sphygmomanometers.
  • Page 6: Touch Button Switch

    DN:KD-7961N-SMSY01 V3.0 Operation Guide Remove the batteries if the monitor will not be used for a month or more to avoid relevant damage of battery leakage. Avoid the battery fluid to get in your eyes. If it should get in your eyes, immediately rinse with plenty of clean water and contact a physician.
  • Page 7: Connecting The Cuff To The Monitor

    DN:KD-7961N-SMSY01 V3.0 Operation Guide language n, and so on. You can select the wanted language by releasing button ―MEM‖ when display the corresponding language code. Picture 4 Picture 4-1 Picture 4-2 Picture 4-3 c. Voice volume setting: Once you have selected a language, a column of bar will appear on the LCD.
  • Page 8: Taking Your Blood Pressure Reading

    DN:KD-7961N-SMSY01 V3.0 Operation Guide Sitting Comfortably Measurement a. Be seated with your feet flat on the floor, and don’t cross your legs. b. Place palm upside in front of you on a flat surface such as a desk or table,...
  • Page 9: Deleting Measurements From The Memory

    DN:KD-7961N-SMSY01 V3.0 Operation Guide Picture 9 Picture 9-1 Picture 9-2 Picture 9-3 d. Press ―MEM‖ button again to review the next result. See picture 9-3. In this way, repeatedly pressing the ―MEM‖ button displays the respective results measured previously. e. If the voice function is on, the monitor will announce each result displaying on the screen.
  • Page 10: Technical Alarm Description

    DN:KD-7961N-SMSY01 V3.0 Operation Guide 12. TECHNICAL ALARM DESCRIPTION The monitor will show 'SYS HI','SYS Lo' ,'DIA HI' or 'DIA Lo' as technical alarm on LCD with no delay if the determined blood pressure (systolic or diastolic) is outside the rated range specified in part SPECIFICACIONS.
  • Page 11: Maintenance

    DN:KD-7961N-SMSY01 V3.0 Operation Guide MAINTENANCE Do not drop this monitor or subject it to strong impact. Avoid high temperature and solarization. Do not immerse the monitor in water as this will result in damage to the monitor. If this monitor is stored near freezing, allow it to acclimate to room temperature before use.
  • Page 12: Warranty Information

    For all ME EQUIPMENT and ME SYSTEMS Guidance and manufacture’s declaration - electromagnetic emissions The KD-7961N is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-7961N should assure that it is used in such an environment. Emissions test...
  • Page 13 Guidance and manufacturer’s declaration - electromagnetic immunity The KD-7961N is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-7961N should assure that it is used in such an environment. Electromagnetic IMMUNITY test...
  • Page 14 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the KD-7961N is used exceeds the applicable RF compliance level above, the KD-7961N should be observed to verify normal operation.
  • Page 15 Operation Guide portable and mobile RF communications equipment and the KD-7961N The KD-7961N is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the KD-7961N can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the KD-7961N as recommended below, according to the maximum output power of the communications equipment.

Table of Contents