Advertisement

DN:KD-5904-SMSY01 V3.0
Fully Automatic Arm Cuff Blood Pressure Monitor
__________________________________________________________________________
IMPORTANT INFORMATION ......................................................................... 2
CONTENTS AND DISPLAY INDICATORS ..................................................... 2
INTENDED USE .............................................................................................. 3
CONTRAINDICATION ..................................................................................... 3
PRODUCT DESCRIPTION .............................................................................. 3
SPECIFICATIONS ........................................................................................... 4
NOTICE ........................................................................................................... 4
SETUP AND OPERATING PROCEDURES .................................................... 6
1.
BATTERY LOADING ............................................................................... 6
2.
Clock Mode .............................................................................................. 6
3.
CLOCK AND DATE ADJUSTMENT ........................................................ 7
4.
VOICE SETTING ...................................................................................... 7
5.
CONNECTING THE CUFF TO THE MONITOR ....................................... 8
6.
APPLYING THE CUFF ............................................................................. 9
7.
BODY POSTURE DURING MEASUREMENT ......................................... 9
8.
TAKING YOUR BLOOD PRESSURE READING ................................... 10
9.
DISPLAYING STORED RESULTS ........................................................ 11
10.
DELETING MEASUREMENTS FROM THE MEMORY ...................... 12
11.
TURNING THE MONITOR POWER OFF ........................................... 12
12.
13.
TROUBLESHOOTING ........................................................................ 13
MAINTENANCE ............................................................................................ 15
EXPLANATION OF SYMBOLS ON UNIT ..................................................... 15
WARRANTY INFORMATION ........................................................................ 16
SERVICE CENTER ....................................................................................... 16
ELECTROMAGNETIC COMPATIBILITY INFORMATION ............................ 16
MODEL KD-5904
(ELECTRONIC SPHYGMOMANOMETER)
OPERATION GUIDE
INDEX
1/14
Operation Guide
Template version:1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KD-5904 and is the answer not in the manual?

Questions and answers

Summary of Contents for Andon KD-5904

  • Page 1: Table Of Contents

    DN:KD-5904-SMSY01 V3.0 Operation Guide MODEL KD-5904 Fully Automatic Arm Cuff Blood Pressure Monitor (ELECTRONIC SPHYGMOMANOMETER) OPERATION GUIDE __________________________________________________________________________ INDEX IMPORTANT INFORMATION ................. 2 CONTENTS AND DISPLAY INDICATORS ............. 2 INTENDED USE ....................3 CONTRAINDICATION ..................3 PRODUCT DESCRIPTION ................3 SPECIFICATIONS ...................
  • Page 2: Important Information

    DN:KD-5904-SMSY01 V3.0 Operation Guide IMPORTANT INFORMATION NORMAL BLOOD PRESSURE FLUCTUATION All physical activity, excitement, stress, eating, drinking, smoking, body posture and many other activities or factors (including taking a blood pressure measurement) will influence blood pressure value. Because of this, it is mostly unusual to obtain identical multiple blood pressure readings.
  • Page 3: Intended Use

    DN:KD-5904-SMSY01 V3.0 Operation Guide INTENDED USE Fully Automatic Electronic Sphygmomanometer is for use by medical professionals or at home and is a non-invasive blood pressure measurement system intended to measure the diastolic and systolic blood pressures and pulse rate of an adult individual by using a non-invasive technique in which an inflatable cuff is wrapped around the upper arm.
  • Page 4: Specifications

    DN:KD-5904-SMSY01 V3.0 Operation Guide SPECIFICATIONS 1. Product name: Blood Pressure Monitor 2. Model: KD-5904 3. Classification: Internally powered, Type BF applied part,IPX0,No AP or APG,Continuous operation 4. Machine size: 145mm×104mm×55mm 5. Cuff circumference: 22cm-30cm, 30cm-42cm(Optional), 42cm-48cm(Optional) 6. Weight: about 300g (exclude batteries) 7.
  • Page 5 DN:KD-5904-SMSY01 V3.0 Operation Guide 1) The application of the cuff over a wound or inflammation diseases; 2) The application of the cuff on any limb where intravascular access or therapy, or an arterio-venous (A-V) shunt, is present; 3) The application of the cuff on the arm on the side of a mastectomy;...
  • Page 6: Setup And Operating Procedures

    DN:KD-5904-SMSY01 V3.0 Operation Guide particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna.
  • Page 7: Clock And Date Adjustment

    DN:KD-5904-SMSY01 V3.0 Operation Guide 3. CLOCK AND DATE ADJUSTMENT When the monitor is turned off, hold on the buttons “Mode” for 3 seconds and the number of the year will blink on and off on the LCD display. In this mode, when the button “Mode”...
  • Page 8: Connecting The Cuff To The Monitor

    DN:KD-5904-SMSY01 V3.0 Operation Guide b. Voice volume setting: Once you have selected a language, again press and hold down the button “MEM”. A line of dashes will appear on the left side of the LCD display and as each new dash appears the monitor will sound a chime. The amount of dashes that appear and the louder the chime sounds, the louder the voice volume is set.
  • Page 9: Applying The Cuff

    DN:KD-5904-SMSY01 V3.0 Operation Guide Avoid compression or restriction of the connection tubing during measurement, which may cause inflation error, or harmful injury due to continuous cuff pressure. APPLYING THE CUFF a. Pulling the cuff end through the medal loop (the cuff is packaged like this already), turn it outward (away from your body) and tighten it and close the Velcro fastener.
  • Page 10: Taking Your Blood Pressure Reading

    DN:KD-5904-SMSY01 V3.0 Operation Guide 8. TAKING YOUR BLOOD PRESSURE READING a. With the cuff wrapped around your arm and your body in a comfortable position, press and release the button “START”. You will hear a beep and the LCD display will first verify itself, then it will set itself to read all zeros.
  • Page 11: Displaying Stored Results

    DN:KD-5904-SMSY01 V3.0 Operation Guide c. The monitor will pump up the cuff; then release the air pressure from the cuff; then show the measurement on the LCD display. If the voice feature is activated, it will announce the blood pressure, heart pulse rate measurements and irregular...
  • Page 12: Deleting Measurements From The Memory

    DN:KD-5904-SMSY01 V3.0 Operation Guide 10. DELETING MEASUREMENTS FROM THE MEMORY When in the memory reading mode, pressing and holding the button “MEM” for 3 seconds will delete all measurements from the memory once the monitor sounds three “beeps”. After the “beeps” the LCD display will show two dashes unless you release the button “MEM”, then the LCD display will show that no measurements are in the memory.
  • Page 13: Troubleshooting

    DN:KD-5904-SMSY01 V3.0 Operation Guide Note: It is not intended to provide a basis of any type of rush toward emergency conditions/diagnosis based on the color scheme and that the color scheme is meant only to discriminate between the different levels of blood pressure.
  • Page 14 DN:KD-5904-SMSY01 V3.0 Operation Guide BPM no response when you Incorrect operation Take out batteries for 5 min press button. BPM hang at least, and then reinstall all batteries. 14/19 JS-KD5904-03-V2.0...
  • Page 15: Maintenance

    DN:KD-5904-SMSY01 V3.0 Operation Guide MAINTENANCE Do not drop this monitor or subject it to strong impact. Avoid high temperature and solarization. Do not immerse the monitor in water as this will result in damage to the monitor. If this monitor is stored near freezing, allow it to acclimate to room temperature before use.
  • Page 16: Warranty Information

    For all ME EQUIPMENT and ME SYSTEMS Guidance and manufacture’s declaration - electromagnetic emissions The KD-5904 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-5904 should assure that it is used in such an environment. Emissions test...
  • Page 17 Guidance and manufacturer’s declaration - electromagnetic immunity The KD-5904 is intended for use in the electromagnetic environment specified below. The customer or the user of the KD-5904 should assure that it is used in such an environment. Electromagnetic IMMUNITY test...
  • Page 18 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the KD-5904 is used exceeds the applicable RF compliance level above, the KD-5904 should be observed to verify normal operation.
  • Page 19 DN:KD-5904-SMSY01 V3.0 Operation Guide disturbances are controlled. The customer or the user of the KD-5904 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the KD-5904 as recommended below, according to the maximum output power of the communications equipment.