Installation; Side-By-Side; Location; Climate Range - Miele KFN 37432 iD Operating And Installation Instructions

Table of Contents

Advertisement

Side-by-side

The KFNS 37432 iD freezer has two
foamed in side-wall heaters enabling
them to be installed side-by-side with
other appliances. Each appliance must
be installed in its own niche.
Your dealer will be able to advise you
on which combination of models is
possible.
This appliance must be built in, oth‐
erwise it could tip up.

Location

This appliance should not be installed
where it is exposed to direct sunlight or
directly adjacent to a heat-producing
appliance such as an oven or a radiator.
The higher the ambient temperature of
the room, the more energy the appli‐
ance requires to operate. The appliance
should be installed in a dry, well ventila‐
ted room.
When installing the appliance, please
note:
– The socket must be easily accessible
in an emergency, not concealed be‐
hind the appliance.
– The plug and cable must not touch
the rear of the appliance as they
could be damaged by vibrations from
the appliance.
– Do not plug in other appliances be‐
hind this appliance.
Important. In environments with
high humidity condensation can build
up on external appliance panels. This
can lead to corrosion of the panels.
For prevention, it is advisable to install
the appliance with sufficient ventila‐
tion in a dry and/or an air-conditioned
room. Please ensure that the appli‐
ance doors close properly, the ventila‐
tion gaps are not covered over and
the appliance is installed in accord‐
ance with these installation instruc‐
tions.

Climate range

The appliance is designed for use with‐
in a certain climate range (ambient tem‐
peratures) and should not be used out‐
side this range. The climate range of the
appliance is stated on the data plate in‐
side the appliance.
Climate range
SN
N
ST
T
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the internal tem‐
perature in the appliance to rise with
the risk of food deteriorating and going
off.

Installation

Ambient room
temperature
+10 °C to +32 °C
+16 °C to +32 °C
+16 °C to +38 °C
+16 °C to +43 °C
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kfns 37432 id