Viessmann VITODENS 242-F Technical Manual page 59

Gas condensing storage combi boiler
Table of Contents

Advertisement

Design information
Connection sets for installation on finished walls, for connection to the left or right
Connection set without pre-mounting bracket, part no. 7347 985
410
410
50
398
361
K
H
A
G
B
F
C
E
D
D
E
C
F
B
G
A
H
A Solar return R ¾/Ø 22 mm
B Heating flow R ¾
C DHW R ½
D Gas connection R ½
E DHW circulation R ½ (separate accessory)
Type
Vitodens 242-F, B2UA
Note
The adjustable feet give the height measurements of the connections
a tolerance of + 15 mm.
For connecting on-site lines on the gas, heating water and DHW sides
from the left or right.
Connection set comprising:
■ Connection pipes
■ Shut-off valves for heating water flow and return, with boiler drain &
fill valve
VITODENS
(cont.)
a
b
c
mm
mm
mm
1367
1422
1477
F Cold water R ½
G Heating return R ¾
H Solar flow R ¾/Ø 22 mm
K Balanced flue connection towards the back
d
e
f
mm
mm
mm
1532
1587
1592
■ 2 connectors for DHW
■ 2 connectors each for solar flow and return (R¾/Ø 22 mm)
■ Gas shut-off valve with thermally activated safety shut-off valve
g
h
k
mm
mm
mm
1696
1752
1807
VIESMANN
6
l
mm
2002
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 333-fVitodens 222-f

Table of Contents