Viessmann VITODENS 242-F Technical Manual page 25

Gas condensing storage combi boiler
Table of Contents

Advertisement

Vitodens 242-F, type B2UA
Vitodens 242-F, 5.2-26 kW
400
40
L
K
350
H
G
300
30
F
E
250
D
200
20
C
150
B
100
10
A
50
0
0
0
100
200
Flow rate in l/h
K Upper operational limit
Curve
Pump rate, circulation
pump
A
10 %
B
20 %
C
30 %
D
40 %
E
50 %
F
60 %
G
70 %
H
80 %
K
90 %
L
100 %
Variable speed solar circuit pump in the Vitodens 242-F
The integral solar circuit pump is a highly efficient circulation pump with
substantially lower power consumption than conventional pumps.
The min. and max. speed and thus the pump rate are set via codes on
the control unit. The control unit transmits the current default settings
to the circulation pump via an internal data BUS.
In the delivered condition, the minimum pump rate (coding address
"05" in the solar group) is set to 30 %. The maximum pump rate (coding
address "06" in the solar group) is set to 100 %.
VITODENS
(cont.)
300
400
500
600
Coding address setting "E6"
E6:010
E6:020
E6:030
E6:040
E6:050
E6:060
E6:070
E6:080
E6:090
E6:100
700
800
900
1000
Type
Rated voltage
Power consumption
Max.
Min.
M
1100
1200
1300
1400
VI Solar PM2
15-85
V~
W
W
VIESMANN
3
230
55
3
25