Operation; Know The Generator - Generac Power Systems 005802-2 XG Professional Series Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

2.1 KNOW THE GENERATOR

Read the entire Owner's Manual and Safety Rules before
operating this generator.
Compare the generator to Figures 3 through 6 to become
familiarized with the locations of various controls and adjustments.
Save this manual for future reference.
1. Choke Knob – Used when starting a cold engine (Pull/Push).
2. Engine Switch – Controls the operation of the generator. On
this electric start model the switch is Start/Run/Stop.
3. Fuel Shut Off – Valve between fuel tank and carburetor. Turn
off and run carburetor out of fuel for extended storage.
4. Panel LED's – Provide illumination of the control panel while
the generator is operating.
5. 120/240 Volt AC, 30 Amp Locking Receptacle – Supplies
electrical power for the operation of 120 and/or 240 Volt AC,
30 Amp, single-phase, 60 Hz, electrical lighting, appliance,
tool and motor loads.
6. 120 Volt AC, 20 Amp, GFCI Duplex Receptacle – Supplies
electrical power for the operation of 120 Volt AC, 20 Amp,
single-phase, 60 Hz electrical lighting, appliance, tool and
motor loads. It also provides protection with an Integral
Ground Fault Circuit Interrupter, complete with a press to
"Test" and "Reset" button.
7. 120/240 Volt AC, 50 Amp Receptacle – Supplies electrical
power for the operation of 120/240 Volt AC, 42 Amp, single-
phase, 60 Hz motor loads.
8. Circuit Breakers (AC) – Each 20 Amp receptacle is provided
with a push-to-reset circuit breaker to protect the generator
against electrical overload.
9. Circuit Breakers (AC) – The 30 Amp receptacle is protected
with a push-to-reset circuit breaker to protect the generator
against electrical overload. The 50 Amp receptacle and one 30
Amp receptacle use toggle reset circuit breakers. The 42 Amp,
2-pole circuit breaker adjacent to the 50 Amp receptacle must
be in the ON position for all the other receptacles to provide
output power.
10. PowerBar – Indicates the amount of power being used from
the generator; each section is approximately 25%.
11. Hourmeter – Provides operating hours for Service Intervals.
12. Battery Charger Input – This receptacle allows the capability
to recharge the 12 VDC engine starting battery with the 12 Volt
Adaptor Plug Charger. The battery is protected by a 1.50 Amp
in-line fuse which is inside the control panel.
13. Fuel Tank – Tank holds 10 U.S. gallons of fuel.
14. Fuel Gauge – Shows fuel level in tank.
15. Handles – Pivot and retract for storage. Press the spring-
loaded button to move handles.
16. Oil Fill – Check oil level and add oil here.
17. Engine Oil Filter – Filters engine oil; see Section 3.1 for the
proper service intervals.
18. Air Filter – Filters intake air as it is drawn into the engine.
19. Spark Plug Location – The spark plugs ignite the Air/Fuel
Mixture.
20. Muffler – Includes the spark arrestor and quiets the engine.
21. Oil Drain – Drain valve to remove used oil from the engine
crankcase.
22. 12 Volt (18 Amp Sealed Battery) – Used to start engine.
23. Grounding Lug – Ground the generator to an approved earth
ground here. See "Grounding the Generator" for details.
24. Roll Over Valve - Passes fuel vapors to the engine.
25. Evap Hose - Installed between the roll over valve and the
engine.
Figure 3 – Generator & Engine Locations

Operation

5