SET UP DEHUMIDIFIER FOR INSTALLATION
CONTROL LOCATION
The on-board control can be located on the top of the
dehumidifier or can be relocated to the front of the
dehumidifier if the control can not be seen/accessed in
the top orientation .
To move the control:
1 . Remove the front control panel cover .
2 . Remove the filter access door and filter .
3 . Detach the on-board control by removing the four
(4) screws around the control . NOTE: Use one hand
to support the bottom of the on-board control when
removing .
4 . Keep the control in the unit and relocate to the front
access hole .
5 . Secure the control with the same four screws used
to attach the control to the top of the unit .
6 . Secure the control panel cover to the top of the unit .
(CONTINUED)
FIGURE 4 – Control Location
CONTROL
CONTROL
PANEL COVER
CONTROL
PANEL COVER
CONTROL
FILTER ACCESS DOOR
90-2017
5