INSTALLING THE DEHUMIDIFIER

DEHUMIDIFIER LOCATION

Electrical service access and drain cleaning will
require the removal of the electrical service side
panel (see Figure 12) . Allow sufficient space for
service on this side of the unit .
The filter can be removed from either side of the
dehumidifier . Allow sufficient space for the filter to
be removed and reinstalled .
If locating the unit where it is not readily accessible
(such as a crawl space, an attic or even a
basement for some individuals), consider controls
such as the Model 76 Dehumidifier Control, which
can be mounted in the living space and wired to
the dehumidifier .
For attic installations, suspending the dehumidifier is
recommended .
Always install the dehumidifier in or above a
condensate pan when locating in or above a
finished space .
1
6
5
Figure 12: Filter Access Clearance
1 - Electrical Service
and Drain Access
this Side
2 - 6" Minimum
Clearance for
Proper Airflow
8 English
2
6"
4
15"
3
90-1840
3 - 15" Minimum
Clearance for
Filter (Either Side)
4 - Filter
5 - Top View
6 - 6' Power Cord
LEVELING AND RAISING THE
DEHUMIDIFIER
The feet can be adjusted to level the unit and
accommodate drain fittings and condensate pans
as required . Use the top-mounted bubble level to
adjust the feet until the bubble is within the outer circle
(see Figure 13) . Leveling is required to ensure proper
drainage from the dehumidifier .
If installing a condensate pump to the side of the
unit more elevation than can be provided by the
adjustable feet may be needed . Risers or hanging kits
are available to lift the dehumidifier higher off the floor .
1
4
3
Figure 13: Leveling the Unit
1 - Bubble Level
2 - Bubble Level Detail
INSTALLING A CONDENSATE PAN UNDER
THE DEHUMIDIFIER
Always install the dehumidifier in or above a
condensate pan when locating it above a finished
space . Adhere to local codes regarding draining of
the condensate pan . If a condensate pump is needed,
make sure it is in the condensate pan as well . Install
a float switch in the condensate pan and/or use the
overflow wires/terminals on the condensate pump
to stop the dehumidifier should overflow occur . See
Wiring to a Float Switch on page 12.
2
OK
OK
NO
90-2692
3 - 3/4" Drain
4 - 0 . 3 8" Minimum
2 . 0 0" Maximum