Initialization; Initial Locale Judgment/Settings - Casio SE-S100 Service Manual

Hide thumbs Also See for SE-S100:
Table of Contents

Advertisement

3. INITIALIZATION

Important:
Main PCB (E261-1 PCB) supplied as spare parts have been pre-installed application and diagnostic
software without LOCALE code.
Then LOCALE code should be set at fi rst when you replace a main PCB from spare parts in your stock.

Initial LOCALE judgment/settings

Remove the memory protection batteries from battery compartment and unplug the power cord
from AC outlet.
After 10sec. or more, set the memory protection batteries into battery compartment and plug the
power cord into AC outlet.
Does LOCALE information exist ?
Does Flash ROM information exist ?
( Restore INIT )
Tips:
Regarding to deletion of the LOCALE information
In diagnostic program mode, input the following command.
2 1 6 o
Yes
Yes
Does LOCALE information exist ?
Diagnostic program mode
Set LOCALE code.
Command: d1 d2
Yes
End
SE-S100 / PCR-T285 / PCR-T295
No
Set the Mode switch to the position other than [OFF].
After IPL is completed.
0016 o
No
Unplug from AC outlet.
Wait 10 sec., then plug into AC outlet.
Go to the setting procedure by destination.
– 3 –
No
d1 d2: LOCALE code
10
EU
20
US
30
UK
50
CANADA
60
Other areas

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcr-t295Pcr-t285

Table of Contents