5-4. Test Procedures

[1] Status Display

[Function]
Displays the device status.
* The device status is not displayed on the customer display.
[Display]
Display
Mode Switch Status
1
2
3
4
5
6
Drawer Status
On
Off
SD Status
On
Off
Descriptions
PGM (programming)
RF (refund)
REG (register)
CAL (calculation)
X (read)
Z (reset)
Drawer is open
Drawer is close
SD card is inserted
SD card is not inserted
SE-S100 / PCR-T285 / PCR-T295
Display
Paper Status
On
Off
Platen Arm Status
On
Off
Battery Status
On
Off
– 23 –
Descriptions
No paper
Paper is set
Platen arm is open
Platen arm is set
Low battery
Normal