Ipl (Initial Program Loader); Initialization - Casio SE-S100 Service Manual

Hide thumbs Also See for SE-S100:
Table of Contents

Advertisement

2. IPL (INITIAL PROGRAM LOADER)

Important:
Main PCB (E261-1 PCB) supplied as spare parts have been pre-installed application and diagnostic
software at the timing of product.
So check the version number of main PCB you replaced and install an appropriate application software,
if necessary.
2-1. Preparation
Prepare the SD card which contains the APLI module (IPL fi le) in the root directory.
2-2. Procedure
(1) Unplug the power cord.
(2) Turn the Mode switch to [PGM], then while pressing f , plug the power cord.
(3) When a pip sound is heard and "BT INT" is displayed, release f .
(4) Insert the SD card into the SD card slot.
(5) 4 4 4 4 9 9 9 9 o
(6) 3 0 o
IPL runs.
(7) When IPL is completed:
Without LOCALE information
With LOCALE information
YY XX
YY: Depends on the application.
XX: Counts up from 1 to YY, and stops at YY.
YY XX
Since the diagnostic program automatically runs, carry out the
LOCALE setting.
Refer to the fl ow in "Initial LOCALE judgment/settings" (P3).
Proceeds to the language setting.
Refer to the setting fl ows by destination (P4 to 7).