SE-S100 / PCR-T285 / PCR-T295 1. SPECIFICATIONS 1-1. Electrical Specifi cations Power Consumption 120 V 230 V 240 V In operation Max. 360 mA 240 mA 240 mA Mode off Max. 30 mA 40 mA 40 mA Memory protection Back-up battery Mangan Battery (UM-3×2 pcs)
Page 4
SE-S100 / PCR-T285 / PCR-T295 2. IPL (INITIAL PROGRAM LOADER) Important: Main PCB (E261-1 PCB) supplied as spare parts have been pre-installed application and diagnostic software at the timing of product. So check the version number of main PCB you replaced and install an appropriate application software, if necessary.
SE-S100 / PCR-T285 / PCR-T295 3. INITIALIZATION Important: Main PCB (E261-1 PCB) supplied as spare parts have been pre-installed application and diagnostic software without LOCALE code. Then LOCALE code should be set at fi rst when you replace a main PCB from spare parts in your stock.
Page 6
SE-S100 / PCR-T285 / PCR-T295 Setting for EU From “Initial LOCALE judgment/settings” Danish, Norwegian and Finnish Language selection Other than Danish, Norwegian and Finnish Date setting Time setting ( Initialization ) Tax setting Rounding setting ( Initialization ) Completion of destination setting...
Page 7
SE-S100 / PCR-T285 / PCR-T295 Setting for US From “Initial LOCALE judgment/settings” Spanish Language selection English Date setting Time setting ( Initialization ) Tax setting ( Initialization ) Completion of destination setting – 5 –...
Page 8
SE-S100 / PCR-T285 / PCR-T295 Setting for UK From “Initial LOCALE judgment/settings” Date setting Time setting ( Initialization ) Ireland Country selection Tax setting ( Initialization ) Completion of destination setting – 6 –...
Page 9
SE-S100 / PCR-T285 / PCR-T295 Setting for CANADA From “Initial LOCALE judgment/settings” French Language selection English Date setting Time setting ( Initialization ) Tax setting Rounding setting ( Initialization ) Completion of destination setting – 7 –...
Page 10
SE-S100 / PCR-T285 / PCR-T295 Setting for other areas From “Initial LOCALE judgment/settings” Arabic Vietnamese Language selection English French Spanish Date setting Time setting ( Initialization ) Country selection Malaysia Australia Singapore Other countries New Zealand Malaysian GST Australian GST...
SE-S100 / PCR-T285 / PCR-T295 4. DISASSEMBLY 4-1. Important • Please note that the product on this manual may appear to be different from the actual one according to the changes such as engineering design change. • Be sure to unplug the power cord before starting any repair/maintenance.
Page 12
SE-S100 / PCR-T285 / PCR-T295 4-2. Flowchart * See the fl owchart below for the order of disassembling major components. A. Replacement of detachable parts of the product S-type M-type Drawer Type? B. MAIN-UNIT (S-type Drawer) B. MAIN-UNIT (M-type Drawer) D.
Page 13
SE-S100 / PCR-T285 / PCR-T295 B. MAIN-UNIT (S-type Drawer) B-1. Remove the cable tie. B-2. Pull the drawer release lever and then remove the drawer. [NOTE] In case the drawer is locked with a drawer lock key, the lever does not activate.
Page 14
SE-S100 / PCR-T285 / PCR-T295 B-6. Remove the cable tie. B-7. Disconnect the DRAWER connector. Cable tie Connector B-8. Undo fi ve screws and remove the COVER/PCB. Screw (S4) + Washer NOTES ON ASSEMBLY: • Fasten together the SHEET/SHIELD/LCD and the COVER/PCB.
Page 15
SE-S100 / PCR-T285 / PCR-T295 C. MAIN-UNIT (M-type Drawer) C-1. Remove the cable tie. C-2. Pull the drawer release lever and then remove the drawer. [NOTE] In case the drawer is locked with a drawer lock key, the lever does not activate.
Page 16
SE-S100 / PCR-T285 / PCR-T295 C-6. Remove the cable tie. C-7. Disconnect the DRAWER connector. Cable tie Connector C-8. Undo one screw. Screw (S9) + Washer Y DRAEWR CASE Copper foil tape/20x40 COVER/TOP Cloth tape/25x50 HOLD/ROM COVER/PCB COVER/CORD + Screw (S3)
Page 17
SE-S100 / PCR-T285 / PCR-T295 D. PS-ASSY (PS-UNIT, DISPLAY-UNIT) D-1. Undo four screws. D-2. Disconnect the connector and FFC. D-3. Remove the PS-ASSY. Screw (S3) Screw (S3) Screw (S8) Screw (S8) Connector PS-ASSY NOTES ON ASSEMBLY Be sure that the LCD surfaces are clean.
Page 18
SE-S100 / PCR-T285 / PCR-T295 Y PS-UNIT (1) Peel off the tape. (2) Remove the MOUNT/PS-UNIT. Cloth tape/19x20 MOUNT/PS-UNIT + PS-UNIT DISPLAY-UNIT NOTES ON ASSEMBLY: PS-UNIT • When the PS-UNIT is replaced with a new part, attach the cable tie and tape.
Page 19
SE-S100 / PCR-T285 / PCR-T295 Y DISPLAY-UNIT FRAME/DISPLAY DISPLAY-UNIT CABLE/FFC/JOINER SHEET/SHIELD/LCD (1) FRAME/DISPLAY Disengage two hooks and remove the FRAME/DISPLAY. FRAME/DISPLAY Hooks (2) SHEET/SHIELD/LCD It is fi xed with two double faced tapes. D-TAPE/SHEET SHEET/SHIELD/LCD – 17 –...
Page 20
SE-S100 / PCR-T285 / PCR-T295 E. MODE KEY F. MOTOR MODE KEY MOTOR Hook Screws (S3) Connector G. PCB ASSY/E286-1 G-1. Undo one screw and then remove the HOLDER/IC. G-2. Undo three or fi ve screws. S-type: S5 M-type: S5 4, S7 G-3.
Page 21
SE-S100 / PCR-T285 / PCR-T295 H. MOUNT/PCB H-1. Undo four screws. H-2. Remove the MOUNT/PCB. Screw (S3) MOUNT/PCB Screws (S7) I. PRINTER I-1. Open the Platen arm I-2. Undo two screws. I-3. Remove the PRINTER. Screw (S3) PRINTER STOPPER Screws (S6)
Page 22
SE-S100 / PCR-T285 / PCR-T295 J. KEY BOARD UNIT Screw (S3) J-1. Undo two screws. J-2. Release two hooks and remove the CHASSIS/KEY BOARD. Hooks CHASSIS/KEY BOARD Screws (S3) Screws (S10) SPACER SPRING/PRESS/B SHEET/COMMON – 20 –...
Page 23
SE-S100 / PCR-T285 / PCR-T295 5. DIAGNOSTIC PROGRAM 5-1. Launching the Diagnostic Program How to launch the diagnostic program (1) Set a paper roll. (2) While pressing f , turn the Mode Switch to [PGM]. (3) Release f . (4) When the following screen appears, press 9 9 9 9 0 0 0 0 o to start the diagnostic program.
Page 24
SE-S100 / PCR-T285 / PCR-T295 5-3. Test Item This diagnostic program tests the following items. Item Command Status Display – Batch Test 1 (RAM / printer/ time setting / buzzer / drawer) Batch Test 2 (main display, customer display) Memory Test...
Page 25
SE-S100 / PCR-T285 / PCR-T295 5-4. Test Procedures [1] Status Display [Function] Displays the device status. * The device status is not displayed on the customer display. [Display] Display Descriptions Display Descriptions Mode Switch Status Paper Status PGM (programming)
Page 26
SE-S100 / PCR-T285 / PCR-T295 [2] Batch Test 1 [Function] RAM, printer, time setting, buzzer and drawer tests are performed continuously. [Operation] Command : 1 o Performs the following tests in sequence. * Refer to each test item for details.
Page 27
SE-S100 / PCR-T285 / PCR-T295 [4] RAM Test (write / read) [Function] Write/read test is performed. [Operation] 0 1 1 o Command : n: Number of times to run Once (can be omitted) Infi nite loop (to forcibly terminate the test, press y .)
Page 28
SE-S100 / PCR-T285 / PCR-T295 [6] SD Card Test (write / read, report) <6-1. SD Card Write/Read Test> [Function] Writes the text fi le for the test (test.txt) on the SD card and tests whether the written fi le can be read.
Page 29
SE-S100 / PCR-T285 / PCR-T295 [7] Display Test [Function] Tests the Main Display and Customer Display. [Operation] All test procedures are the same for both tests except for the input command. 0 2 1 o Main display command : 0 2 2 o...
Page 30
SE-S100 / PCR-T285 / PCR-T295 [8] Main Display Backlight Test [Function] Tests the Main Display backlight. [Operation] 0 1 2 1 o Command : c: Backlight ON/OFF Backlight “OFF” Backlight “ON” with any key Backlight “OFF" Backlight “ON"...
Page 31
SE-S100 / PCR-T285 / PCR-T295 [10] Internal Printer Character Print Test [Function] Tests if the internal printer prints characters correctly. [Operation] 0 3 3 o Command : a: Printing property Normal print out Reduced size print out c: Characters to be printed Prints the character “B”...
Page 32
SE-S100 / PCR-T285 / PCR-T295 [11] Time & Date Setting / Time & Date Display [Function] Allows you to check or change the time (hour, minutes, seconds) and date (year, month, day) that are currently set. * The time and date are not displayed on the customer display.
Page 33
SE-S100 / PCR-T285 / PCR-T295 [13] Buzzer Test [Function] Tests whether buzzer sounds correctly. [Operation] 0 9 2 o Command : n: Number of times to run Once (can be omitted) Infi nite loop (to forcibly terminate the test, press y .) 1 to 9 •...
3. The numbers in item column correspond to the same numbers in drawing. 4. CASIO does not supply the spare parts without parts code. 5. Refer to the latest “Parts Price Code” at “PARTS FINDER” on the Casio Service WEB site (https://www.servicecasio.com).