INSTALLATION INSTRUCTION

1) Connect the main circuit cable of the wire feeder to the corresponding output end of the machine, and fasten with
bolts.
2) Connect the plug of the control circuit 6-core cable of the wire feeder to the corresponding interface of the machine
and lock.
3) Connect the plug of earth wire to the corresponding output end of the machine, and fasten with bolts.
4) Install the CO
gas meter on the gas cylinder; connect the trachea of the wire feeder to the CO
2
5) Plug the welding gun to the welding gun output socket of the wire feeder and rotate 45°clockwise. Tighten the welding
gun fastening screws with in turn spanner so as that the welding gun contacts with the wire feeder output socket
reliably. Connect the controller plug and the gas connection to the wire feeder.
6) Install the wire reel loaded with welding wire on the shaft bracket of the wire feeder, select different wire feeding
groove according to the welding wire diameter.
7) Loosen the pressure arm, feed the welding wire into wire feeding pipe through gadget wheel and groove. Press the
pressure arm so that the wire pressing wheel presses the welding wire tightly to prevent the welding wire from sliding.
Do not push the pressure arm too hard; prevent the welding wire from deformation and interfering with wire feeding.
The welding wire roll rotates clockwise to loosen the welding wire. In order to prevent the leading end of wire reel from
loosening, it is generally fixed to the fixing hole of the wire reel. Cut off this part of welding wire to prevent the winding
welding wire from getting struck during normal operation.、
8) Explanation to the polarity conversion: this machine has the polarity conversion function. When use solid wire in work,
polarity conversion quick-plug on panel should be connected to positive output terminal.
When use self shielded flux-cored welding wire, the above said quick-plug should be connected to negative output
terminal, the workpiece connected to positive output terminal.
9) This procedure shall be operated by electrician!
Connect proper power cord to the distribution box with corresponding capacity according to the input voltage and
current of the welding machine (See technical parameter table). Do not connect to the inappropriate voltage and
make sure that the difference of power supply is within permitted range.