Notes Or Preventive Measures - zika MIG 200G Owner's Manual

Table of Contents

Advertisement

NOTES OR PREVENTIVE MEASURES

1. Environment
1) The machine can perform in environment where conditions are dry with a dampness level of max 90%.
2) Ambient temperature is between -10 to 40 degrees centigrade.
3) Avoid welding in sunshine or drippings. Do not let water enter the gas
4) Avoid welding in dust area or the environment with corrosive gas.
5) Avoid gas welding in the environment with strong airflow.
2. Safety norms
Our welding machine has installed protection circuit of over voltage, over current and over heat. When voltage, output
current and temperature of machine are exceeding the rated standard, welding machine will stop working
automatically. Because this will be damage to welding machine, user must pay attention to following.
1) The working area is adequately ventilated!
Our welding machine is powerful machine, when it is being operated, it generated high currents, and natural
wind cannot satisfy with machine cool demands. So there is a fan inside the machine for its cooling demands.
Make sure the intake is not in block or covered, there should be 0.3 meter distance from welding machine to
objects of environment. User should make sure the working area is adequately ventilated. It is important for the
performance and the longevity of the machine.
2) Do not over load!
The operator should remember to watch the max duty current (Response to the selected duty cycle) Welding
current should not exceed max duty cycle current. Over-load current will damage and burn up the machine.
3) No over voltage!
Power voltage can be found in diagram of main technical data. Automatic compensation circuit of voltage will
assure that welding current keeps is in allowable range. If power voltage is exceeding allowable range limits, it
can damage the components of machine. The operator should understand this situation and take preventive
measures.
4) There is a grounding screw behind welding machine, with a grounding marker on it. Before operation, welding
crust must be grounded reliably with cable which section is over 6 square millimeters, in order to prevent from
static electricity, and accidents because of electricity leaking.
5) If welding time is exceeding duty cycle limited, welding machine will stop working for protection. Because
machine is overheated, temperature control switch is on "ON'' position and the indicator light is red. In this
situation, you don't have to pull the plug, let the fan cool the machine. When the indicator light is off, and the
temperature goes down to the standard range, it can weld again.