Trouble Shooting; Specifications - Tennant Typhoon MWD16BATTN Operator's Manual

Wet/dry battery vacuum
Table of Contents

Advertisement

EN
ENGLISH

TROUBLE SHOOTING

PROBLEM
No power.
Poor pick–up.
Short run time.

SPECIFICATIONS

Model No.
LENGTH
WIDTH
HEIGHT
WEIGHT – WEIGHT WITH BATTERIES
VACUUM MOTOR
SEALED WATER LIFT
BATTERIES
RUN TIME on full charge
DECIBEL RATING AT OPERATOR'S EAR, INDOORS ON TILE
12
Home
CAUSE
Faulty ON/OFF switch
Batteries need charging.
Faulty battery(s).
Loose battery cable.
Batteries are not connected
correctly.
Vacuum motor thermal overload
tripped.
Faulty vacuum motor wiring.
Air flow obstruction.
Vacuum bag is full.
Ball float screen is activated.
Drain hose plug is loose or off.
Cover latches are not engaged.
Batteries need charging.
Worn cover gasket.
Vacuum motor carbon brushes worn. Contact Service Center.
Batteries not fully charged.
Faulty battery(s).
Batteries need maintenance.
Faulty charger.
Find...
Go To..
SOLUTION
Contact Service Center.
See Battery Charging
Replace battery(s)
Tighten loose cables.
See Battery Installation.
Check air flow for obstruction, wait
20 minutes for motor to cool.
Contact Service Center.
Remove obstruction from ball float
screen, vacuum hose, accessary
tool or squeegee.
Empty or replace bag.
Drain recovery tank.
Secure drain hose plug.
Engage cover latches.
Charge batteries.
Replace gasket.
Charge batteries.
Replace battery.
See Battery Maintenance.
Replace charger.
MWD16BATTN
84cm/33"
53 cm/21"
109cm/43"
41 Kg/90 lbs – 107Kg/235 lbs
24V, 3–stage, .75hp, 23A, 566W
178cm/70"
2–12V deep cycle lead acid, 105AH or 130AH
4 hours
>70dB(A)
Typhoon (8–96)

Advertisement

Table of Contents
loading

Table of Contents