According to VESA power saving signal. TCO03 power saving requirement
EPA energy star requirement
(Power Switch Off)
For digital input power consumption is less 1W
(In non-DMPM recoverable off mode)
3.6
Display identification
3.6.1
In accordance with VESA Display Channel Standard V1.0 and having
DDC-2B capability.
4.0
Visual characteristics
4.1
Test conditions
Unless otherwise specified, this specification is defined under the
following conditions.
(1) Input signal: As defined in 3.3, 1280 x 1024 non-interlaced mode
(2) Luminance setting: Contrast 50% , brightness :100%
(3) Warm up: more than 30 minutes after power on with signal supplied.
(4) Ambient light: 400 -- 600 lux.
(5) Ambient temperature: 20 ±5 °C
4.2
Resolution
Factory preset modes (15 modes)
# Resolution H-Frequency Pixel rate V-Frequency
1
640X350
2
720X400
3
640X480
4
640X480
5
640X480
6
800X600
7
800X600
17 inch LCD Monitor
TYPE
BRAND : PHILIPS
2004-06-08
Jerry Chen/Peter V
(80K/75Hz), signal sources must have 75 ohm
output impedance.
31.5KHz
25.175
31.5KHz
28.322
37.5KHz
31.501
35.0KHz
30.24
31.5KHz
25.175
35.2KHz
36
46.9KHz
49.498
: 170C5BS/00
2004-06-08
Comment
70Hz
IBM VGA 10h
70Hz
IBM VGA 3h
75Hz
67Hz
60Hz
56Hz
75Hz
8639 000 15502
590
15
26