Display - Inter-m IM-300 Operation Manual

Table of Contents

Advertisement

MAIN CONTROLLER AMPLIFIER/SUB AMPLIFIER/CHAIRMAN UNIT/DELEGATE UNIT

Display

Display
1. IM-300 Main Controller VFD/LED
1) Mode Key: Free Mode and Reserve Mode are repeated whenever pressing this key.
- Free Mode: Displays "FREE 00 0:00" after displaying "FREE".
- Reserve Mode: Displays "WAIT 00(reserved person numbers) 0:00(continued speaking time)" after
displaying "RESERVE".
2) Chime Key: Displays "Chime Play".
3) All Clear Key: Displays "All Clear".
4) 1 Clear Key: Displays "One Clear".
5) Time Set
- In case of 1 minute, displays "SPEAKING TIME 1Min".
- In case of 2 minutes, displays "SPEAKING TIME 2Min".
- In case of 3 minutes, displays "SPEAKING TIME 3Min".
- In case of 4 minutes, displays "SPEAKING TIME 4Min".
- In case of 5 minutes, displays "SPEAKING TIME 5Min".
6) Time Clear Key (IMC-300): Displays "SPEAKING TIME OPEN".
7) USB Memory Stick inserted: Displays "USB Detected".
8) REC Key: "R" flickers for Saving, "R" lights off for Ending.
9) Main Volume – For the VFD, 24 steps are displayed from Volume MIN to Volume MAX. – For a LED, 12
steps are displayed.
10) For chairman's speaking: Displays "Chairman".
11) For calling of emergent speaking: Displays "EDC (Emergency Delegate Call)" mark.
12) Input signal level: Displays 20 levels in the Graphic Level.
2. IMC-300 chairman unit LCD, LED, Gooseneck LED
1) During chairman's speaking: LCD displays "CH", and LED lights up.
2) For calling of emergent speaking: LCD displays "EdC", and LED flickers.
3) Volume Key: Displays "00 - 24".
4) All Clear Key: Displays "A-CL".
5) 1 Clear Key: Displays "1-CL".
6) Time Set
- In case of 1 minute, displays "1-00".
- In case of 2 minutes, displays "2-00".
- In case of 3 minutes, displays "3-00".
- In case of 4 minutes, displays "4-00".
- In case of 5 minutes, displays "5-00".
7) Time Clear Key: Displays "OPEN".
8) Continued speaking time: Continued speaking time is displayed only for delegate unit (IMD-300).
- For the Free Mode, increased speaking time from "0-00" to "9959" is displayed.
- For the Reserve Mode, decreased speaking time from "5-00" to "0-00" is displayed.
14
IM-300, IMS-300, IMC-300, IMD-300

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ims-300Imd-300Imc-300

Table of Contents