ELECTRICAL ADJUSTMENT PROCEDURE IDLE CURRENT A. Connection B. Adjustment – Adjust SVR11, SVR12 so that the current through the R68, R69 become 4~7mV. – When that voltage across the Positive “TP” to Negative “TP” becomes 4~7mV, the current becomes 18~32mA.