Wiring Instructions

The fireplace, when installed, must be
electrically connected and grounded in ac-
cordance with local codes or, in the absence
of local codes, with the current CSA C22.1
Canadian Electric Code.
For USA installations follow the local codes
and the national electrical code ANSI/NFPA
No. 70.
Should this fan require servicing or repair
the power supply must be disconnected.
For rewiring of any replacement parts refer
to Figure 53.
Any electrical re-wiring of this fan must be
done by a licensed electrician.
Temperature Sensor
Speed Control
Black
White
Ground
Fig. 53 FK24 fan wiring.
Ceramic Refractory Panels
Ceramic refractory panels are available for the LDV series
appliances
Kit Model and Finish
Unit
Sandstone
33LDVT 33LDVTCR
36LDVT
GAHC3J0
GAFC3J0
39LDVT
39LDVCR
43LDVT
43LDVCR
Take care when handling the refractory panels
as they are fragile until held in place and
supported.
Installation, refer to Figures 54 & 55
1. Remove the front window frame assembly.
2. Remove the logs.
3. Place the rear refractory panel in place. Locate the lower
edge of the panel in the ledge formed by the top of the
rear log support bracket.
4. Slide the side refractory panels into place to hold the
rear panel secure. Repeat the procedure on the other
side.
5. Replace the logs and window frame assembly.
10007852
Fan
FP1025
FP394
WIRING DIAGRAM
11/20/96
Red
Black
Grey
GABC3J0
GAGC3J0
LDVT Series Direct Vent GaS Fireplace
For aesthetic purposes we recommend
aligning the horizontal mortar lines.
Side
Panel
Log Support
Fig. 54 Ceramic panel installation.
Rear Refractory
Panel
FP1231
Rear Panel Sup-
Ceramic panels
port Brackets
11/02
Rear Log
Support
Fig. 55 Rear refractory panel installation.

Remote Controls

Optional remote control units are available to control
FP1232
different functions of the appliances
rear ceramic panel
Model
Function/s Controlled
11/02
RCI
ON/OFF
RC2
ON/OFF and Temperature.
IMTFK
Wall mounted thermostat control
Back Panel
Burner Tray
Firebox Back
Panel
FP1232
Side
Panel
FP1231