Specifications

Replacement light bulb
Mains power required
Suitable for
Stand-by power consumption
Operating power consumption
Net weight
Trolley speed
Rated force
Standard pole length
Standard assembled overall length
Standard trolley travel
Minimum headroom required
Minimum backroom required
Ambient operating temperature
Overall dimensions
E27 45mm Round, 40W maximum, RC preferred
220V to 240 V, 50 Hz, single phase AC, earthed
sectional doors, one piece tilt doors. Note that counterweight
type doors are not suitable for automating
3 W
900 W
15kg (installed using typical pole and strapping)
depending on sprocket and load: 75 to 135mm/sec
770N
2750mm to suit chain supplied
pole length + 400mm = 3150mm
pole length - 275mm = 2480mm
100mm between the top edge of the door and the ceiling
while the door is closing or opening
600mm back from the rear edge of a fully opened door,
depends on door arm chosen.
0
+5
C to +40
3150 (Standard)
Minimum 453
0
C.
Minimum 215
15